WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
Revision C
Troubleshooting
Overview
49
Confidential
During printing
After starting to print, ink is not
ejected and paper stops midway.
Relay Head FFC 1. Check that the Relay Head FFC is securely connected to the
Main Board connectors CN11, CN12, and CN13.
2. Check that the Relay Head FFC is securely connected to the CR
Relay Board connectors CN3 and CN4.
1. Connect the Relay Head FFC to the Main
Board connectors CN11, CN12, and CN13.
2. Connect the Relay Head FFC to the CR Relay
Board connectors CN3 and CN4.
3. Check the Relay Head FFC for damages.
3. Replace the Relay Head FFC with a new one.
Head FFC
1. Check that the Head FFC is securely connected to the CR Relay
Board connectors CN1 and CN2.
2. Check that the Head FFC is securely connected to the Print
Head connectors.
1. Connect the Head FFC to the CR Relay Board
connectors CN1 and CN2.
2. Connect the Head FFC to the Print Head
connectors.
3. Check the Head FFC for damages.
3. Replace the Head FFC with a new one.
Ink is not ejected from most
nozzles.
Print Head
1. Check for occurrence of Head Hot.
1. Replace the Print Head with a new one.
Table 3-11. Troubleshooting of Fatal Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point
Remedy
Relay Head FFC
Head FFC
Print Head
connector
Head FFC
Содержание WorkForce 1100
Страница 8: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 21: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 29: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 61: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 128: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 152: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 162: ...Confidential C H A P T E R 7 APPENDIX ...