WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
Revision C
Troubleshooting
Overview
54
Confidential
Horizontal or vertical
banding / Getting
smeared
Although inks are ejected from
the Print Head to the Cap, the
trouble still occurs after
executing a cleaning cycle or
replacing the Ink Cartridges.
Head FFC
3. Check the Head FFC for damages.
3. Replace the Head FFC with a new one. If the
trouble still occurs after replacing it, replace the
Print Head with a new one.
Print Head
1. Check if the print quality recovers after running a cleaning or
replacing the Ink Cartridges.
1. Run the cleaning and replace the Ink Cartridges
several times. If the trouble still occurs, replace
the Print Head with a new one.
Main Board
1. Check the Main Board for damages.
1. Replace the Main Board with a new one.
Table 3-12. Print Quality Troubles
Observed Faults
Details of the Fault
Faulty Part/
Part Name
Check Point
Remedy