WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
Revision C
Troubleshooting
Overview
44
Confidential
At power-on
While the power-on sequence is
being executed, Fatal error is
displayed.
APG Sensor
1. Check the APG Sensor connector cables is connected to the
APG Sensor connectors.
2. Check if the connector cables of the APG Sensor is broken.
1. Connect the APG Sensor connector cables to
the APG Sensor connectors.
2. Replace the ASF Assy with a new ones.
3. Check the APG Sensors for damages.
3. Replace the APG Assy with a new one.
Table 3-11. Troubleshooting of Fatal Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point
Remedy
APG Sensors
APG Sensor connector cables
Содержание WorkForce 1100
Страница 8: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 21: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 29: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 61: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 128: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 152: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 162: ...Confidential C H A P T E R 7 APPENDIX ...