WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100
Revision C
Disassembly And Assembly
Removing the Sensors
126
Confidential
4.6.4 PE Sensor Holder
1.
Remove the ASF Assy. (p.96)
2. Remove the PE Sensor connector cable from the five tabs on the Release Holder
Assy and the two tabs on the Head Cable Cover.
Figure 4-162. Releasing the Cables
3. Release the tabs that secure the PE Sensor Holder from the notch on the Main
Frame with a flathead screwdriver, and slide the PE Sensor Holder upwards and
then remove it toward you.
Figure 4-163. Removing the PE Sensor Holder
Make sure that the PW Sensor FFC is routed as shown in
Figure
4-161
A D J U S T M E N T
R E Q U I R E D
After replacing or removing the PW Sensor, always make the required
adjustments referring to the following.
“Chapter 5
Adjustment
(p.128)
”
PE Sensor connector cable
Tabs
Release Holder Assy
Tabs
Head Cable Cover
PE Sensor Holder
Front Side
Tab