25. Disconnect the Sensor FFC from the connector on the CR Encoder Board, pull out
the Sensor FFC from the Carriage Unit, and remove the Carriage Unit.
Figure 4-81. Removing the Carriage Unit
4.4.6 ASF Assy
1.
Remove the Upper Housing Support Assy. (p.74)
2. Remove the C.B.S. M3 x 8 screw that secures the Earth cables on the right rear
side of the printer, and remove the Earth cables.
3. Disconnect the ASF Motor connector from the Relay connector.
4. Disconnect the Relay connector cable from the ASF Assy.
Figure 4-82. Releasing the Cables (1)
A D J U S T M E N T
R E Q U I R E D
After replacing or removing the Carriage Shaft and Carriage Unit,
always make the required adjustments referring to the following.
“Chapter 5
Adjustment
(p.128)
”
A D J U S T M E N T
R E Q U I R E D
After replacing or removing the Carriage Shaft and Carriage Unit,
be sure to perform the required lubrication referring to below.
“Chapter 6
Maintenance
(p.152)
”
CR Encoder Board
Sensor FFC
Secure the two Earth cables together with the screw.
Referring to
Figure 4-82
, correctly route the Relay connector
cable.
Relay
connector
Relay
connector
cable
Earth cables
5) C.B.S. M3x8
(8±1 kgf.cm)
ASF Motor
ASF Assy
Содержание WorkForce 1100
Страница 8: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 21: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 29: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 61: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 128: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 152: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 162: ...Confidential C H A P T E R 7 APPENDIX ...