2. Installation
Safety and Installation (T, VT / EPSON RC+ 7.0) Rev.15
55
WARNING
■
Use an earth leakage breaker on the power cable of the Manipulators
to avoid electric shock and circuit breakdown caused by short circuit.
■
For DC specification Manipulator, use a circuit protector to avoid electric
shock and/or malfunction of the robot system.
CAUTION
■
When cleaning the Manipulator, do not rub it strongly with alcohol or
benzene. It may lose luster on the coated face.
2.4.3 Noise level
Manipulator Level dB(A)
Operating conditions
Measurement point
T series
70 or under
Rated load
4-joints simultaneous
motion
maximum speed
maximum
acceleration/deceleration
Duty 50%
Rear of the
Manipulator,
1,000 mm apart from
the motion range, 50
mm above the base-
installed surface
VT series
70 or under
Rated load
All joints simultaneous
motion
maximum speed
maximum
acceleration/deceleration
Duty 50%
1,000 mm apart from
the rear of the
Manipulator