2 PinS anD PaCKaGeS
S1C63003/004/008/016 TeChniCal Manual
Seiko epson Corporation
2-5
(Rev. 1.1)
Pin name
Pad/pin No.
I/O OP SFT
Function
Default
Shared
function
Chip
QFP15/
TQFP14
P40
P40
22
97
I/o OP
– I/O port pin
SEG36
O OP
– LCD segment output pin
P41
P41
21
96
I/o OP
– I/O port pin
SEG37
O OP
– LCD segment output pin
P42
P42
20
95
I/o OP
– I/O port pin
SEG38
O OP
– LCD segment output pin
P43
P43
19
94
I/o OP
– I/O port pin
SEG39
O OP
– LCD segment output pin
P50
P50
9
84
I/o OP
D I/O port pin
RFOUT
O
SFT R/F converter CR oscillation clock output pin
SEG48
O OP
– LCD segment output pin
P51
P51
8
83
I/o OP
D I/O port pin
SEN0
O
SFT R/F converter Ch.0 CR oscillation output pin for DC bias sensor
SEG49
O OP
– LCD segment output pin
P52
P52
7
82
I/o OP
D I/O port pin
REF0
O
SFT R/F converter Ch.0 CR oscillation output pin for reference resistor
SEG50
O OP
– LCD segment output pin
P53
P53
6
81
I/o OP
D I/O port pin
RFIN0
I
SFT R/F converter Ch.0 CR oscillation input pin
SEG51
O OP
– LCD segment output pin
RFin1
RFIN1
4
79
I
OP
– R/F converter Ch.1 CR oscillation input pin
SEG52
O OP
– LCD segment output pin
ReF1
REF1
3
78
O OP
– R/F converter Ch.1 CR oscillation output pin for reference resistor
SEG53
O OP
– LCD segment output pin
Sen1
SEN1
2
77
O OP
– R/F converter Ch.1 CR oscillation output pin for DC bias sensor
SEG54
O OP
– LCD segment output pin
huD
HUD
1
76
O OP
– R/F converter CR oscillation output pin for AC bias sensor
SEG55
O OP
– LCD segment output pin
COM0–COM7
67–60
42–35
O
–
– LCD common output pins
SeG0–SeG35
59–24
34–1,
100, 99
O
–
– LCD segment output pins
ReSeT
82
62
I
–
– Initial reset input pin
TeST
81
61
I
–
– Test pin (Connect to V
SS
during normal operation.)
I/O: Capital letters (I, O) represent the input/output direction in the initial settings.
OP: Selected by mask option ("–" means "no option provided.")
SFT: Switched by software ("–" means "no software switch provided" and "D" means default function.)
Note: The TEST terminal must be connected to the V
SS
power supply. Be sure to avoid applying other
conditions to the terminals during normal operation.