46
3.5.5. Valores orientativos de velocidad máxima de
cabina
A modo orientativo, se presenta la siguiente tabla con
las velocidades a las que normalmente un ascensor se
mueve
asumiendo
máximo
desequilibrio
consumiendo menos de la potencia nominal del
convertidor DC/DC.
3.5.1. Maximum cabin speed guide values
Following table shows maximum speed guide values,
assuming maximum load, so that power consumption
does not exceed the nominal power of the DC/DC
converter.
Carga máxima ascensor
[kg]
Maximum elevator load
[kg]
Tipo de instalación
Installation type
EPCL 3k5
Velocidad máxima [m/s]
Maximum speed [m/s]
EPCL 5k5
Velocidad máxima [m/s]
Maximum speed [m/s]
300
Pórtico/ Hanger
1*
1*
300
Mochila/ Rucksack
1*
1*
450
Pórtico/ Hanger
Entre 0.7 y 1**
1*
450
Mochila/ Rucksack
Entre 0.5 y 1**
1*
600
Pórtico/ Hanger
Entre 0.5 y 0.85**
0.95**
600
Mochila/ Rucksack
Entre 0.5 y 0.80**
0.75**
Tabla 2. Velocidades máximas orientativas/ Maximum cabin speed values.
INICIO
Configura el ascensor a la menor velocidad
mostrada en la Tabla 1 «Velocidades máximas
orientativas» según el tipo de instalación y la
carga máxima.
Realice un trayecto de bajada con la cabina
vacía (trayecto de máximo consumo)
¿Se ha realizado el viaje exitosamente
(no se ha parado el variador y el consumo es
menor que potencia nominal)?
Realiza diez ciclos de subida y de
bajada para comprobar la correcta
instalación.
Reduce la velocidad de cabina 0.1 m/s
¿Ha surgido algún
problema en esos
viajes?
Reduce 0.1 m/s la
velocidad
SI
SI
NO
NO
Aumente 0.1 m/s la
velocidad
Realiza diez ciclos de subida y de
bajada para comprobar la correcta
instalación.
¿Ha surgido algún
problema en esos
viajes?
FIN
SI
NO
Reduce 0.1 m/s la
velocidad
START
Setup the elevator speed with the lowest
possible one shown in Table 1
“Orientative
maximum speed” depending on the type of
installation and the maximum load
Proceed with a downward trip with no load in
the car (maximum conssumption trip)
Repeat 10 cycles of upward and
downward trips
Reduce the speed by 0.1 m/s
Has there been a
problem?
Reduce 0.1 m/s the
speed
YES
YES
NO
NO
Increase the speed
by 0.1 m/s
Repeat 10 cycles of upward and
downwart trips to veryfy the
correct setup
Has there been a
problem?
END
YES
NO
Reduce 0.1 m/s the
speed
Is the trip successful? (drive
has not stopped and conssumption is
less than the nominal power.
Содержание P2S Series
Страница 1: ...1 Manual de instalaci n Installation guide P2S Series plug single phase P2S powered by...
Страница 2: ...2 Versi n 4 6 June 2018 Epic Power Converters S L...
Страница 9: ...9 Fig 3 Convertidor DC DC 5k5 5k5 DC DC Converter 0 1 2 3 4 6 10 9 7 8 5...
Страница 55: ...55 Dimensiones EPCL 5K5 EPCL 5k5 dimensions...
Страница 56: ...56 6 6 Dimensiones del cargador de bater as 6 6 Battery charger dimensions...
Страница 57: ...57 6 7 Dimensiones del inversor monof sico 6 7 Single phase inverter dimensions Inversor TS 400 TS 400 Inverter...
Страница 58: ...58 Inversor TS 700 TS 700 Inverter...
Страница 59: ...59 6 8 Dimensiones del Controlador de carga solar 6 8 Solar charge controller dimensions...
Страница 61: ...61 6 9 2 Bastidor bater as Small 4x1 6 9 2 Small batteries rack 4x1...
Страница 62: ...62 6 9 3 Bastidor bater as Medium 6 9 3 Medium batteries rack...