VENTILADORES:
Importante
dejar
despejadas las salidas y entradas de aire.
0)
FANS: It is important to leave the fan outputs and
inputs unobstructed.
1)
SALIDAS A LA MANIOBRA:
IMPORTANTE
: Se tratan de contactos libres de
potencial. Las salidas no deben someterse a
tensiones
superiores
a 24V en continua o
250Vac, ni a corrientes superiores a 5A.
-
1A) COMÚN: Conexión común de los
terminales 1B, 1C, 1D, 1E y 1F.
-
1B) STATUS OK: (Normally Open) Con
circuito cerrado a común indica que el
convertidor DC/DC tiene habilitada la salida
de tensión al bus en el variador y por lo
tanto este se encuentra alimentado.
-
1C) LOW BATTERY 1 (Normally Close): Con
circuito abierto indica Estado de Carga de
baterías < 30%.
-
1D) LOW BATTERY 1 (Normally Open): Con
circuito cerrado a común indica Estado de
Carga de baterías < 30%.
-
1E) LOW BATTERY 2: (Normally Open) Con
circuito cerrado a común indica Estado de
Carga de baterías< 60%.
-
1F) AC CHARGER ON: (Normally Open) Con
circuito cerrado a común indica a la
maniobra que el cargador de red está
funcionando correctamente.
-
1G) DETECCIÓN DE DERIVA (Normally Open).
-
1H) No conectado.
El estado de los contactos en función del estado
de carga de las baterías (SoC) es el siguiente:
[cerrado=0, abierto=1]
1)
OUTPUTS TO CONTROLLER:
IMPORTANT
: These are potential-free contacts.
These outputs should never withstand voltages
higher
than 24V DC or 250V AC. These outputs
should never conduct currents higher than 5A.
-
1A) COMMON: Common connection of
terminals 1B, 1C, 1D, 1E y 1F.
-
1B) STATUS OK: (Normally Open). When this
terminal is short-circuited to common it
indicates that the DC/DC converter is in
operation and therefore, it is supplying the DC
link of the drive, so the drive is energized.
-
1C) LOW BATTERY 1 (Normally Closed): When
this terminal is open, it indicates SOC < 30%.
-
1D) LOW BATTERY 1 (Normally Open): When
this terminal is short-circuited to common it
indicates SOC < 30%.
-
1E) LOW BATTERY 2 (Normally Open): When
this terminal is short-circuited to common it
indicates SOC < 60%.
-
1F) AC CHARGER ON: (Normally Open): When
this terminal is short-circuited to common it
indicates to the controller that the battery
charger is working properly.
-
1G) EARTH LEAKEAGE DETECTION (Normally
Open).
-
1H) No connect.
The condition of the contacts depending on the
State Of Charge (SOC) of the batteries is:
[closed=0, open=1]
0
Содержание P2S Series
Страница 1: ...1 Manual de instalaci n Installation guide P2S Series plug single phase P2S powered by...
Страница 2: ...2 Versi n 4 6 June 2018 Epic Power Converters S L...
Страница 9: ...9 Fig 3 Convertidor DC DC 5k5 5k5 DC DC Converter 0 1 2 3 4 6 10 9 7 8 5...
Страница 55: ...55 Dimensiones EPCL 5K5 EPCL 5k5 dimensions...
Страница 56: ...56 6 6 Dimensiones del cargador de bater as 6 6 Battery charger dimensions...
Страница 57: ...57 6 7 Dimensiones del inversor monof sico 6 7 Single phase inverter dimensions Inversor TS 400 TS 400 Inverter...
Страница 58: ...58 Inversor TS 700 TS 700 Inverter...
Страница 59: ...59 6 8 Dimensiones del Controlador de carga solar 6 8 Solar charge controller dimensions...
Страница 61: ...61 6 9 2 Bastidor bater as Small 4x1 6 9 2 Small batteries rack 4x1...
Страница 62: ...62 6 9 3 Bastidor bater as Medium 6 9 3 Medium batteries rack...