11
MODO/
MODE
CONDICIÓN/
CONDITION
Estado del contacto
1C/ 1C contact state
Estado del contacto
1D/ 1D contact state
Estado del contacto
1E/ 1E contact state
Estado variador/
VVVF state
1
SoC >= 60%
Cerrado/ close (0)
Abierto/ open(1)
Abierto/ open (1)
ON
2
30% <= SoC <
60%
Cerrado/ close (0)
Abierto/ open (1)
Cerrado/ close (0)
ON
3
SoC < 30%
1
Abierto/ open (1)
Cerrado/ close (0)
Abierto/ open (1)
ON
4
SoC <= 15%
2
Abierto (1)
Cerrado (0)
Cerrado (0)
OFF
1
No se debe comenzar un viaje de ascensor
estando en modo 3.
2
Cuando el equipo pasa a modo 4, el variador de
velocidad estará apagado.
1
A elevator trip must not be carried out in mode
3.
2
If mode 4 is active, the VVVF will be disconnected.
Tabla 2. Estado de carga según contactos/ State of charge depending on contacts.
2)
CONTROL DE ELEMENTOS AUXILIARES:
-
2A) y 2B) RC IN y -: Deshabilita el
ondulador bajo petición de la maniobra a
través de la entrada ENABLE INV (3C). En
caso de apagar el DC/DC con el interruptor
“ON OFF”, el “Inversor monofásico” será
deshabilitado.
-
2C) y 2D) (Remote Control) RC C y
-: Deshabilita el cargador de baterías
mediante cortocircuito entre 2C y 2D.
o
Esta deshabilitación será realizada
automáticamente
por
el
Convertidor DC/DC en caso de
disponer del accesorio “Regulador
de Carga Solar” y de que exista
energía suficiente por parte de las
placas solares. En este caso el
consumo de red será nulo
2)
OUTPUTS to AUXILIARY ELEMENTS:
-
2A) and 2B) RC IN and -: The inverter
can be disabled by controller requirement
using input ENABLE INV (3C). If the DC/DC
converter is turned off with the main switch,
the inverter will also be disabled.
-
2C) and 2D) (Remote Control) RC C
and -: A short-circuit between terminals 2C
and 2D disables the battery charger.
o
The DC/DC converter disables the
charger when the solar regulator is in
operation and if there is enough
solar energy from the solar panels (if
you have acquired this item). In this
particular case, the consumption
from mains would be zero.
Содержание P2S Series
Страница 1: ...1 Manual de instalaci n Installation guide P2S Series plug single phase P2S powered by...
Страница 2: ...2 Versi n 4 6 June 2018 Epic Power Converters S L...
Страница 9: ...9 Fig 3 Convertidor DC DC 5k5 5k5 DC DC Converter 0 1 2 3 4 6 10 9 7 8 5...
Страница 55: ...55 Dimensiones EPCL 5K5 EPCL 5k5 dimensions...
Страница 56: ...56 6 6 Dimensiones del cargador de bater as 6 6 Battery charger dimensions...
Страница 57: ...57 6 7 Dimensiones del inversor monof sico 6 7 Single phase inverter dimensions Inversor TS 400 TS 400 Inverter...
Страница 58: ...58 Inversor TS 700 TS 700 Inverter...
Страница 59: ...59 6 8 Dimensiones del Controlador de carga solar 6 8 Solar charge controller dimensions...
Страница 61: ...61 6 9 2 Bastidor bater as Small 4x1 6 9 2 Small batteries rack 4x1...
Страница 62: ...62 6 9 3 Bastidor bater as Medium 6 9 3 Medium batteries rack...