Relay Box for Infrared Cabins - Installation Instructions
65
Commissioning
7.5 Setting the heating period limiter
For private use, the heating period is limited to 6 h.
For commercial use, the heating period can be set to 6 h, 12 h or infinite.
The codes for the heating period limiter are exclusive to infrared-only
installations.
In mixed operation, IR emitters are installed in a sauna cabin. For this instal-
lation, the heating period limiter is set with jumper 5 on the sauna relay
box,. This overrides the codes listed above.
Setting the heating period
1
Tap and hold
for 3 seconds.
2
Enter the code and confirm.
Code
8206
: 6 hours.
Code
8212
: 12 hours.
Code
8224
: 24 hours/7 days a week.
Heating period
Code
6 hours
8206
12 hours
8212
Unlimited 24 hours/7 days a
week
8224
0
1 2 3
4 5 6
7 8 9
C
Setting
Code
08:44:40
01. June 2019