STEP 3: SETTING BACK CHECK
TOP VIEW
DOOR HELD AT 90% OF FULLY OPEN
HOLD UPPER LIMIT SWITCH
IN PLACE WHILE DOOR IS 90%
OF FULLY OPEN POSITION
BOTTOM VIEW
SET LOWER LIMIT SWITCH IN LINE WITH
REED SWITCH TERMINAL THAT ALIGNS
TO ‘OPEN BACK CHECK’ ON THE LABEL
OPEN
BACK CHECK
1-877-348-6837
switch
CLOSE LATCH
AUTO.
OFF
ON
White
Black
Red
HOLD OPEN
OFF
ON
Low Profile
WL-PA03
Date:
FINAL POSITIONS
DOOR FULLY OPEN
(TOP VIEW)
LOWER LIMIT SWITCH
PASSES LOWER REED
These switch positions will vary
depending on your install and/or
site conditions. Door openings
smaller or larger than 90 degrees
will also have different positions
for each switch.
IMPORTANT: Back Check and
Latch Check occurs at 10 degrees
before fully open and fully close
position, respectively.
DOOR FULLY CLOSED
(TOP VIEW)
UPPER LIMIT SWITCH
PASSES UPPER REED
4.0 OPERATOR TUNING
WITH “SPINDLE OPENING ROTATION” LABEL