Entrematic Canada Inc.
Toll Free: 1-877-348-6837
[email protected]
www.ditecentrematic.ca
Entrematic USA Inc.
Toll Free: 1-866-901-4284
[email protected]
www.ditecentrematic.us
Pg. 34
HA8-LP Manual V. 4.0
STEP 1: SETTING LATCH CHECK
LOWER LIMIT SWITCH
DOOR STARTS
IN FULLY CLOSE POSITION
TOP VIEW
UPPER LIMIT SWITCH
SET UPPER LIMIT SWITCH IN
LINE WITH REED SWITCH
TERMINAL THAT ALIGNS TO
'CLOSE LATCH' ON THE LABEL
BOTTOM VIEW
WITH “SPINDLE OPENING ROTATION” LABEL
OPEN
BACK CHECK
1-877-348-6837
switch
CLOSE LATCH
AUTO.
OFF
ON
White
HOLD OPEN
Black
OFF
Red
ON
STEP 2: OPEN DOOR TO BEFORE BACK CHECK
DOOR 90% OF FULLY OPEN POSITION
(81 FOR A 90 OPEN DOOR)
TOP VIEW
DOOR HELD AT 90% OF FULLY OPEN
4.0 OPERATOR TUNING
Low Profile
WL-PA03
Date:
Cover Plate
Operator/Gearbox