Entrematic Canada Inc.
Toll Free: 1-877-348-6837
[email protected]
www.ditecentrematic.ca
Entrematic USA Inc.
Toll Free: 1-866-901-4284
[email protected]
www.ditecentrematic.us
Pg. 52
HA8-LP Manual V. 4.0
9.3 Programming Specification
FUNCTION
SETTING
FUNCTION DESCRIPTION
DEFAULT
LED
LED
SETTING
0
0 to F
0 = slowest
F = fastest
OPENING SPEED DOOR 1
A
1
0 to F
0 = slowest
5 = fastest
OPENING SPEED DOOR 2
A
2
0 to 5
0 = slowest
5 = fastest
BACK CHECK SPEED DOOR 1
2
3
0 to 5
0 = slowest
5 = fastest
BACK CHECK SPEED DOOR 2
2
4
0 to 5
0 = slowest
5 = fastest
LATCH SPEED DOOR 1
5
5
0 to 5
0 = slowest
5 = fastest
LATCH SPEED DOOR 2
5
6
0 to 5
0 = slowest
5 = fastest
HOLD SPEED DOOR 1
2
7
0 to 5
0 = slowest
5 = fastest
HOLD SPEED DOOR 2
2
1 = 1 sec
6 = 6 sec
b = 12 sec
ACTIVATION TIME
The time that the door remains open,
starting when the activation trigger goes OFF.
1 to 30 sec
2 = 2 sec
7 = 7 sec
C = 14 sec
8
3 = 3 sec
8 = 8 sec
d = 15 sec
5
4 = 4 sec
9 = 9 sec
E = 25 sec
5 = 5 sec
A = 10 sec
F = 30 sec
0 = 0.00 sec
SAFETY 1 INHIBIT
1 = 0.50 sec
The time that a Safety1 input is ignored
9
2 = 1.00 sec
(inhibited), starting when one of the
0
3 = 1.50 sec
doors go into Latch.
4 = 2.00 sec
0 to 2 sec
A
0 = 0.00sec
1 = 0.25sec
2 = 0.50sec
3 = .075sec
4 = 1 sec
5 = 2 sec
6 = 3 sec
7 = 4 sec
8 = 5 sec
DELAY ON OPERATE DOOR 1
The time delay before operating door #1, starting when
the activation # 2 trigger goes ON.
0 to 5sec
Note that ACT=N1 input always provides an instant
0
trigger while ACT=N2 input provides a delayed trigger.
0 = 0.00sec
4 = 1 sec
DELAY ON OPERATE DOOR 2
The time delay before operating door #2, starting when
the activation # 2 trigger goes ON.
0 to 5sec.
Note that ACT=N1 input always provides an instant
trigger while ACT=N2 input provides a delayed trigger.
1 = 0.25sec
5 = 2 sec
b
2 = 0.50sec
3 = 0.75sec
6 = 3 sec
7 = 4 sec
0
8 = 5 sec
C
Special Function selection - see next chart
0 = 0.00 sec
Delay on Closing
One of the doors delays before closing for the chosen
time. 0 to 2sec. Application Code AC4” states
which door delays.
1 = 0.50 sec
D
2 = 1.00 sec
0
3 = 1.50 sec
4 = 2.00 sec
9.0 DUAL BOARD & PROGRAMMING