9.1
Dual Door Digital Board Specification (Fully Automatic only)
INPUTS
AC VOLTAGE
ACTIVATION 1 (ACT=N1)
ACTIVATION 2 (ACT=N2)
SAFETY 1
SAFETY 2
- Single input for both doors. ON = Closed contact to ground/common.
- See setting C1 for operation description.
- Single input for both doors. ON = Closed contact to ground/common.
- See setting C1 for operation description.
- Single input for both doors. Closed contact to ground/common.
- For Safety1 ON (closed to ground) door will not open if presently fully closed and door will
not close if presently fully opened.
- Single input for both doors. Closed contact to ground/common.
- For Safety2 ON (closed to ground) and activation input ON (closed to ground) door will drive
at hold speed. If activation input goes off door closes. If Safety2 goes off door will open.
OUTPUTS
MOTOR
DATA
_
and DATA+
- 2 motor connectors for each door (4 total).
- Doors can drive in clockwise or counter clockwise direction.
- Interface with BEA Bodyguard sensor. (replaces LO-21K lockout relay)
OTHER FEATURES
Safety Monitoring is turned OFF as a default. To turn Safety monitoring ON see programming
SAFETY MONITORING
CLOSING SPEED
BACK CHECK SWITCH
LATCH SWITCH
LOCKOUT
OVERLOAD
HOLD OPEN SWITCH
ON SWITCH
settings C8, C9, CA, and CB. Connection diagram on next page shows sensors wired in safety
monitoring configuration.
Adjustable by potentiometer. 1 potentiometer for each door
Power off does not affect closing speed
1 switch for each door (Magnet and Reed switch)
1 switch for each door (Magnet and Reed switch)
Each door has separate lockout which is selectable via Setting C2
Each door has a non-adjustable overload.
A switch wired one side to the HOLD OPEN quick disconnect tab and the other side to the OFF
quick disconnect tab will open both doors and keep them open until the switch is turned off. *
A switch wired one side to the ON quick disconnect tab and the other side to the OFF quick
disconnect tab provides the door ON function. This switch, when open, disables the motors and
all inputs but does NOT turn the board power off. *
* The Hold Open Switch and the ON Switch come wired to a single 3 position switch where the middle position gives Door OFF,
one side provides Hold Open, and the last side provides Door ON or Automatic.
9.0 DUAL BOARD & PROGRAMMING
LINE VOLTAGE
TRANSFORMER (Hammond)
120VAC 60Hz
#166N24
– 24VAC – 4AMP
240VAC 50Hz
#266N24
– 24VAC – 4AMP