Entrematic Canada Inc.
Toll Free: 1-877-348-6837
[email protected]
www.ditecentrematic.ca
Entrematic USA Inc.
Toll Free: 1-866-901-4284
[email protected]
www.ditecentrematic.us
Pg. 53
HA8-LP Manual V. 4.0
CODE INDICATION
LED 1 = ON
LED 1 = OFF
DEFAULT
SETTING
FUNCTION
LED
SETTING
LED
C
0
Safety 2 OFF at back check
Safety2 always active
LED OFF (Safety
2 always active)
C
1
ACT=N1 is connected to a push button
switch and always opens the door.
ACT=N2 is connected to the door and
is only active after ACT’N1 is pressed
and before the door closes and gets to
the Latch point.
Activation input 1 (ACT=N1)
works as an instant activation.
Activation input 2 (ACT=N2)
works as a delayed activation
(delay time programmed through
Function A5@.)
LED OFF
ACT=N1
is instant;
ACT=N2
is delayed
activation
C
2
Lockout ON
– during closing Safety1
is active if the door stops moving (from
hitting an obstruction for example). If
door is moving then Safety1 is NOT
active.
Lockout OFF
Safety1 is always active
LED ON
(Lockout ON)
C
3
To obtain the number of opening cycles that the door has gone through press the
set button while in the Function C, Setting 3 mode.
Example: Readout of 3 2 (pause) 7 0 = 3,270 door cycles.
The display will read
- -
at the end of readout
C
4
Door 1 delays before closing for the
amount of time setup in Function AD@
Door 2 delays before closing
for the amount of time setup in
Function AD@
LED ON
(Door 1 delays)
C
5
Safety1 sensor mounted on
closing side of door
Safety1 sensor mounted overhead
LED OFF
–
Safety1 mounted
overhead
C5 - LED OFF
(Overhead
Sensor)
Door Opening
- Safety1 sensor has no effect
Door Fully Open - Safety1 sensor ON = door will not close
Door Closing
- C2 setting ON. Door moving = Safety1 has no effect (door will open)
- C2 setting ON. Door stopped, Safety1 ON = door will not open
- C2 setting OFF. Safety1 ON = door will not open
Door fully closed - Safety1 sensor ON = door will not open
C5 - LED ON
(Door mounted
Sensor)
Door Opening
- Safety1 sensor has no effect
Door Fully Open - Safety1 sensor ON = door will not close
Door Closing
- Safety1 sensor ON = door drives at HOLD speed
Door fully closed - Safety1 sensor has no effect
9.0 DUAL BOARD & PROGRAMMING