46
IP2266EN
EN
i
Parameters from C0 to C9= FUTURE USE.
Operator mode selector service indication (00÷01)
Yellow flashing service LED.
Service indication on operation mode selector.
No service indication (00).
Indicate service (01).
00
= Off
01
= On
Choose priority of the operation mode selector (25÷99)
FUTURE USE
Choose group of the operation mode selector (00÷10)
FUTURE USE
Choose display mode of the operation mode selector (00÷01)
In Show local mode the OMS shows the last setting made
on the OMS.
In Show system mode the OMS shows the setting that the
operator is put to. It is shown with one flach every 5s.
When the OMS is flashing every 5s it is not possible to change
the mode on the OMS.
00
= Show system mode.
01
= Show local mode.
AUTOMATIC
Choose terminal mode of the operation mode selector (00÷02)
00
=The buttons on OMS are disabled.
01
= The OMS adapts to system mode.
02
= The OMS keeps its selected mode.
AUTOMATIC
Mode selector, self service indication 00÷01)
COM500ES/ER
. Orange flashing service LED.
COM501ES/ER
. Magenta flashing service LED.
Self service indication on operation mode selector.
00
= Off. No self service indication.
01
= On. Indicate self service. Indicating a status or condition
that can be cleared by the owner e.g. a break-out door
is standing open.
Mode selector, key impulse (00÷02)
Key impulse to the operator can be made in the following
ways by pushing the symbol below.
COM500ES/ER
,
COM501ES/ER
,
00
= Disabled. Disables the possibility to give key impulse.
01
= Login Required. Login required on the OMS to enable
the possibility to give key impulse.
The login is configured through parameter 99 and b1.
02
= Enabled. Enables the possibility to always give key
impulse.
Bluetooth Power Mode (00÷02)
00
= Always disabled. The Bluetooth Power Mode is fully
disabled until other mode is set.
01
= Disabled in OFF mode. The Bluetooth Power Mode is
disabled in OFF mode.
02
= Always enabled. The Bluetooth Power Mode is fully
enabled until other mode is set.