22
IP2266EN
EN
Output
Description
A
Power supply unit connection
B
Motor connection
C
Encoder connection
D
green LED
jumper
Connection for:
- Program selector;
- Network connection of interconnected operators;
- Connector for Bluetooth interface;
Green LED
: If this LED is switched off or flashing, it means the control
panel is malfunctioning.
JUMPER
: For interconnecting more than two units (control unit and/or
operation mode selectors).
E
DAS901BAT1 - DAS902BAT2 battery kit connection (optional)
In the event of a power failure the operator will carry out an opening
operation (factory setting).
See parameters 10, 38 , 40 and 41 for selection of continuous operation
and monitoring with DAS902BAT2.
NOTE
: Monitoring will be made if parameter 10 is set to Convenience
Monitoring (01).
To charge the batteries, connect the mains power and the battery kit at
least 30 minutes before starting the system.
WARNING
: for charging purposes, the battery kit must be connected to
the control panel at all times. Periodically check the efficiency of the
battery kit. When there is no voltage, the door can only be opened with
a KEY com-mand connected between 8-12.
NOTE
: use battery type 12V, 1,2mAh NiMH.If a different type of battery is
used it can damage!
F
DAS200RG motor connection