35
IP2266EN
EN
LOCK parameters
Parameter
Description
Range
05
Lock configuration (main control). No lock (10) / antipanic (11) / standard and
bistable (12)
10÷12
06
Lock release. Off (00) / On (01)
00÷01
43
Opening delay for lock
00÷99s x0,1
44
EXIT lock. Off (00) / On (01)
00÷01
51
Push & Close. Off(00) / On (01)
00÷01
52
Push & Close Timeout
00÷99s x10
98
(DAS902MP)
Lock configuration terminal 16/17. No lock (10) / bistable (11)
10÷11
SENSOR parameters
Parameter
Description
Range
07
Presence impulse 1 configuration. N.O. (00) / N.C. (01)
00÷01
08
Presence impulse 2 configuration. N.O. (00) / N.C. (01)
00÷01
09
Presence impulse monitoring. None(00)/sensor 1(01)/sensor 1 and 2(02)
00÷02 units
16
Inner impulse (motion) monitoring. Off (00) / On (01)
00÷01
27
Side presence input 1 configuration. N.O. (00) / N.C. (01)
00÷01
28
Side presence input 2 configuration. N.O. (00) / N.C. (01)
00÷01
29
Side presence impulse monitoring. None (00) / sensor 1 (01) / sensor 1 and 2 (02) 00÷02 units
30
Side presence activation distance
00÷99dm
31
Sensor type.1-wire (00) / 2-wire (01) monitoring
00÷01
45
STOP function. Off (00) / On (01)
00÷01
46
STOP configuration. N.O. (00) / N.C. (01)
00÷01
91
(DAS902MP)
Function select terminal 4. No function (00) / Open / Close function (01) / Interlock
disable (02) / inner impulse 2 monitoring (03)
00÷04
93
(DAS902MP)
Function select terminal 2. No function (00) / Close function (01) / inner impulse
2 (03)
00÷03
OPERATION MODE SELECTOR parameters
Parameter
Description
Range
B0
Operation mode selector variant. Electronic program selector (04)
00÷04
B1
Operation mode selector key lock. Off (00) / Hold for 2 s.(01) /Passcode (02) / key (03)
00÷03
B2
Operator mode selector service indication. Off (00) / On (01)
00÷01
B3
Choose priority of the operation mode selector. The lower the number the higher
the priority.
25÷29
B4
Choose group of the operation mode selector.
00÷10
B5
Choose display mode of the operation mode selector. Show system mode (00) /
Show local mode (01)
00÷01
B6
Choose terminal mode of the operation mode selector. The buttons are disabled
(00) / adapts to system mode (01) / it si setting the operation mode (02)
00÷02
B7
Mode selector, self service indication. Off (00) / On (01)
00÷01
B8
Mode selector, key impulse. Disabled (00) / Login required (01) / Enabled (02)
00÷02
B9
Bluetooth Power Mode. Always disabled(00), Disabled in OFF mode(01), Always
enabled (02).
Default(02)
00÷02