45
IP2266EN
EN
Choose group of the DAS902MP operation Mode selector,
terminals 9÷14 (00÷10)
FUTURE USE
ELECTRONIC OPERATION MODE SELECTOR PARAMETERS
Parameter
Description
Factory
setting
Installation
setting
Operation mode selector variant (01÷04)
01
= DO NOT USE.
02
= DO NOT USE.
03
= DO NOT USE.
04
= ELECTRONIC SELECTOR.
AUTOMATIC
Operation mode selector key lock (00÷03)
COM501ES/ER
There are four different levels of access code choices for
the operation mode selector.
COM500ES/ER
There are three different levels of access code choices for
the operation mode selector.
00
= No access code.
01
= Hold for two sec.
COM500ES/ER
, access is obtained by holding
or
for 2 seconds.
COM501ES/ER
, access is obtained by holding any mode
selection button for 2 seconds.
02
= Passcode.
COM500ES/ER
, passcode can be selected where the access
is obtained by briefly pushing in turn
.
The entire passcode must be entered within 3 seconds.
COM501ES/ER
, passcode can be selected where the access
is obtained by briefly pushing the buttons in correct order.
The entire passcode must be entered within 10 seconds.
The passcode can be changed through the DAS900CT.
Default passcode is
.
03
= Key
COM501ER
To enable the use of the selector, rotate the key clockwise
towards the symbol
COM500ER
mode selector is not affected by this parameter.
See parameter 99.