GPV 3KTL/4KTL/5KTL

>

Single-Phase string inverters

Supports up to 150%DC/AC ratio
Fast installation with no led opening necessary
Dual MPPT for flexible installation
Small and light thanks to compact design
IP65 for outdoor use

Differernt color optons available

Содержание GPV3.6KTL

Страница 1: ...e string inverters Supports up to 150 DC AC ratio Fast installation with no led opening necessary Dual MPPT for flexible installation Small and light thanks to compact design IP65 for outdoor use Diff...

Страница 2: ...ated output Protective devices Input side disconnection device Ground fault monitoring Grid monitoring DC reverse polarity protection AC short circuit current capability All pole sensitive residual cu...

Страница 3: ...2 3 Symbols on the label 6 3 Unpacking 7 3 1 Scope of delivery 7 3 2 Checking for transport damage 8 4 Mounting 8 4 1 Requirements for mounting 8 4 2 Mounting the inverter 10 5 Electrical Connection...

Страница 4: ...he network cable 28 5 6 3 Connect the smart meter cable 30 6 Communication 31 6 1 System monitoring via RS485 Ethernet 31 6 2 System monitoring via WLAN 32 6 3 Inverter demand response modes DRED 33 6...

Страница 5: ...nt temperature GPV3KTL 46 9 6 2 Power reduction with increased ambient temperature GPV3 6KTL 46 9 6 3 Power reduction with increased ambient temperature GPV4KTL 47 9 6 4 Power reduction with increased...

Страница 6: ......

Страница 7: ...sks exactly as described All persons installing inverters must be trained and experienced in general safety which must be observed when working on electrical equipment Installation personnel should al...

Страница 8: ...death or serious injury WARNING indicates a hazardous situation which if not avoided can result in death or serious injury CAUTION indicates a hazardous situation which if not avoided can result in m...

Страница 9: ...posed to sunlight a DC voltage is supplied to this equipment 6 All components must remain within their permitted operating ranges at all times 7 The product is also approved for the Australian market...

Страница 10: ...ductors and the live components of the inverter Touching the DC conductors or the live components can lead to lethal electric shocks If you disconnect the DC connectors from the inverter under load an...

Страница 11: ...c shock connect and ground the PV modules array frame and electrically conductive surfaces so that there is continuous conduction Do not ground any of the terminals of the strings Risk of injury due t...

Страница 12: ...ing operation Do not dispose of this inverter with household waste For more information on disposal please refer to Section 13 Recycling and disposal CE mark The inverter complies with the requirement...

Страница 13: ...ors and hexagon bolts 3 M4 10 mm screw 2 1 set D DC connector 2 pairs E AC Plug connector 1 piece F WLAN optional 1 piece optional G Magnetic ring 1 piece H Documentation 1 set I Smart meter terminal...

Страница 14: ...inverter in areas where flammable materials are stored Do not mount the inverter in areas where there is a risk of explosion 1 Be sure the inverter is installed out of the reach of children 2 Mount th...

Страница 15: ...uitable for the inverter s weight and dimensions 9 If mounted in a residential area we recommend mounting the inverter on a solid surface Plasterboard and similar materials are not recommended due to...

Страница 16: ...trical connection area must point downwards 4 2 Mounting the inverter Risk of injury when lifting the inverter or if it is dropped The weight of Solplanet inverter is max 12 kg There is risk of injury...

Страница 17: ...a 10 mm drill The holes must be about 70 mm deep Keep the drill vertical to the wall and hold the drill steady to avoid tilted holes Risk of injury due to the inverter falls down Before inserting the...

Страница 18: ...r and attach it tilted slightly downwards to the wall bracket 4 Check both sides of the heat sink to ensure that it is securely in place 5 Push the inverter as far as possible and attach it to both si...

Страница 19: ...econd protective conductor is required in installation site ground the inverter and secure it so that it cannot drop from the housing see section 5 4 3 Second protective grounding connection Dismante...

Страница 20: ...Do not touch the DC conductors Do not touch any live components of the inverter Have the inverter mounted installed and commissioned only by qualified persons with the appropriate skills If an error o...

Страница 21: ...that a separate DC isolator should be installed next to the inverter The separate DC isolator must disconnect each PV string of the inverter so that the entire inverter can be removed if the inverter...

Страница 22: ...cation cable D GPRS or WiFi optional transmit and receive GPRS or Wi Fi signal E AC OUTPUT plug in connector connect the grid 5 4 AC connection 5 4 1 Conditions for the AC connection Cable Requirement...

Страница 23: ...cable length GPV3KTL GPV3 6KTL GPV4KTL GP5KTL 4 mm 28m 23m 20m 17m 6 mm 42 m 35m 30m 26m The required conductor cross section depends on the inverter rating ambient temperature routing method cable ty...

Страница 24: ...f the AC circuit breaker rating may be necessary due to self heating or if exposed to heat The maximum output current and the maximum output overcurrent protection of the inverters can be found in sec...

Страница 25: ...d carry out one of the following measures Connect a copper wire grounding conductor with a cross section of at least 10 mm to the AC connector bush insert Connect an additional grounding that has at l...

Страница 26: ...t breaker and secure it against being inadvertently switched back on Damage to the inverter due to wrong wiring If the phase line was connected to PE terminal the inverter will not function properly P...

Страница 27: ...locking cap threaded sleeve and swivel nut together When doing so hold the bush insert firmly by the locking cap This ensures that the threaded sleeve can be screwed firmly onto the bush insert Then...

Страница 28: ...lign the terminal lug with the grounding conductor on the screw 3 Tighten it firmly into the housing screwdriver type T20 torque 1 6Nm 1 2 3 Information on grounding components Object Description 1 M4...

Страница 29: ...ors included in the scope of delivery The positive connection cables of the PV modules must be equipped with the positive DC connectors The negative connection cables of the PV modules must be equippe...

Страница 30: ...ctor have the same polarity 3 Press the clamping bracket down until it audibly snaps into place 4 Ensure that the cable is correctly positioned Result Measure If the stranded wires are visible in the...

Страница 31: ...n DC conductors When exposed to sunlight the PV array generates dangerous DC voltage which is present in the DC conductors Touching the DC conductors can lead to lethal electric shocks Cover the PV mo...

Страница 32: ...C input voltage of the inverter it can be destroyed due to overvoltage All warranty claims become void Do not connect strings with an open circuit voltage greater than the maximum DC input voltage of...

Страница 33: ...tration Seal the unused DC inputs so that moisture and dust cannot penetrate the inverter Make sure all DC connectors are securely sealed 6 Ensure that all DC connectors are securely in place 5 6 Conm...

Страница 34: ...communication wiring Internal components of the inverter can be irreparably damaged due to incorrect wiring between the power wire and signal wire All the warranty claim will be invalid Please check...

Страница 35: ...plug from the cable gland and keep it well If there is only one network cable please keep a filler plug in the remaining hole of the sealing ring against water ingress 3 Current pin assignment for the...

Страница 36: ...sing a screwdriver T25 7 Tighten the swivel nut firmly torque 3 0 3 5Nm Make sure the cable gland is mounted properly The cable gland must be adequately locked to prevent any movement of the cable 1 2...

Страница 37: ...tighten the swivel nut Screwdriver type PH2 torque 1 6Nm If communication cover used remove only one sealing plug of the cable gland to thread the cable Detailed installation process follows above st...

Страница 38: ...n at section 6 1 For more information please contact the Service 6 2 System monitoring via WLAN User can monitor the inverter through the external WIFI stick with WLAN module The connection diagram be...

Страница 39: ...e inverter shall detect and initiate a response to all supported demand response commands demand response modes are described as follows Mode Requirement DRM 0 Operate the disconnection device DRM 1 D...

Страница 40: ...able For more information please contact the Service 6 4 Active power control with Smart meter The inverter can control activepower output via connecting smart meter following picture is the system co...

Страница 41: ...ion 7 1 Electrical checks Carry out the main electrical tests as follows Check the PE connection with a multimeter make sure that the inverter s exposed metal surface has a ground connection Danger to...

Страница 42: ...has been correctly mounted with wall bracket Make sure the cover has been correctly mounted Make sure the communication cable and AC connector have been correctly wired and tightened 7 3 Safety code c...

Страница 43: ...ing wrong during checking the inverter will switch to the Fault mode Normal After checking the inverter will switch to Normal state and feed power into the grid During periods of low radiation the inv...

Страница 44: ...er is in Feed in operation with a power of at least 90 of power Blue LED The blue LED flashes during communication with other devices e g AiCom AiManager Solarlog etc Also the blue LED flashes during...

Страница 45: ...e slots and pull the DC connectors out downwards Do not pull on the cable 5 Ensure that no voltage is present at the DC inputs of the inverter 6 Remove the AC connector from the jack Use a suitable me...

Страница 46: ...d active power 3000W 3680W 4000W 5000W Max apparent AC power 3000VA 3680VA 4000VA 5000VA Nominal AC voltage range 220V 230V 180V 295V AC power frequency range 50 60 5Hz Rated power frequency rated gri...

Страница 47: ...udible and visible AU Zero power output Via connecting Smart meter Dimensions W x H x D mm 376x355x145 Weight 12Kg Cooling concept convection Noise emission typical 25 dB A 1m Installation indoor outd...

Страница 48: ...circuit current capability Residual current monitoring GFCI function Earth Fault Alarm cloud based audible and visible AU Protection class according to IEC 62103 overvoltage category according to IEC...

Страница 49: ...on can be changed with a password 9 5 Efficiency The operating efficiency is shown for the three input voltages Vmpphigh Vdc r and Vmpplow graphically In all cases the efficiency refers to the standar...

Страница 50: ...iciency European weighted efficiency 97 85 97 33 MPPT efficiency 99 9 9 5 2 Efficiency curve GPV3 6KTL Efficiency Max efficiency European weighted efficiency 97 85 97 45 MPPT efficiency 99 9 9 5 3 Eff...

Страница 51: ...MPPT efficiency 99 9 9 6 Power reduction In order to ensure inverter operation under safe conditions the device may automatically decrease power output Power reduction depends on many operating parame...

Страница 52: ...o these parameters Notes Values are based on rated grid voltage and cos phi 1 9 6 1 Power reduction with increased ambient temperature GPV3KTL 9 6 2 Power reduction with increased ambient temperature...

Страница 53: ...47 9 6 3 Power reduction with increased ambient temperature GPV4KTL 9 6 4 Power reduction with increased ambient temperature GPV5KTL GPV4KTL GPV3 6KTL...

Страница 54: ...for installation and electrical connections Tools model Object Torque Torque screwdriver T25 Screws for the cover 2 5Nm Torque screwdriver T20 Screw for second protective grounding connection 1 6Nm Sc...

Страница 55: ...ccurs it might be that the internal circuit has broken Contact the service 33 Check the grid frequency and observe how often major Stick Hand tight Socket wrench Open end of 33 Swivel nut of M25 cable...

Страница 56: ...gering of the circuit breaker in the distribution box Check the grid voltage grid usability Check the AC cable grid connection on the inverter If this fault is still being shown contact the service 36...

Страница 57: ...t 1 2 3 4 5 6 8 9 Disconnect the inverter from the utility grid and the PV array and reconnect it after LCD and LED turn off If this fault is still being displayed contact the service Contact the serv...

Страница 58: ...approx 30 minutes before cleaning until the heat sink has cooled down Ground yourself before touching any component Clean the heat sink with compressed air or a soft brush Do not use aggressive chemic...

Страница 59: ...53 62 106 May 22 2014 RED Gsmart Ningbo Energy Storage Technology Co Ltd confirms herewith that the inverters described in this document are in compliance with the fundamental requirements and other r...

Страница 60: ...pe Inverter serial number Type and number of connected PV modules Error code Mounting location Installation date Warranty card Service Contact Our regional services contact information can be found at...

Страница 61: ...g this Warranty will transfer to any subsequent purchaser of that building so long as the Products remain installed at its original place This Warranty only applies where the Products have been instal...

Страница 62: ...k and repaired by Gsmart or Repaired on site or Exchanged with a refurbished inverter that includes all firmware updates If the product needs to be exchanged the remainder of the warranty period will...

Страница 63: ...u or another user have failed to follow any all of the user manual the installation guide and the maintenance regulations 9 The device has been used improperly or misused 10 Insufficient ventilation o...

Страница 64: ...r will not be charged for reasonable costs associated with the making of a warranty claim including warranty processing costs the cost of replacement parts or freight Reimbursement for necessary and r...

Страница 65: ...5609 China Website http www gsmarte com 2 Importer company name Risen Energy Australia Contact number 0390217788 Email info risenenergy com au Address Unit 35 15 Ricketts Road Mount Waverley Victoria...