26
www.enelx.com
Phone: +1-844-584-2329
7. Re-attach front panel wiring
If required, there are three points to
re-connect:
1. Wiring to the top rear panel.
Plug in connector.
2. Earthing strap.
Replace the earthing strap lug on the stud
and secure with the nut using a 10mm
socket.
3. Connector ‘B’ on the HMI panel.
Plug in Connector ‘B’.
1
2
3
8. Attach front panel
Gently place the front panel on the top
hook ensuring the panel sits outside the
fastening brackets. Sit on the radiator
panel and check the top hook is engaged.
It will hold in position. Secure with the
nylon washers and security screws with
the 5mm Pin Hex tool ensuring the plastic
holes line up with the bracket nutserts.
Do not over tighten.
9. Complete installation checklist
Complete the
JuicePump Site
Installation Checklist
, and
return to Enel X.
This must be returned for warranty vali
-
dation.
Closing checklist