3. Prepare remaining Flexa system
Remove the locking ring from the
remaining section of the Flexa system.
Push the flexa conduit into the installed
flex adapter to attach. Attach the top flex
adaptor into the hole inside the service
hatch with the washer on the outside of
the box, and secure inside with the
locking ring.
4. Feed through wiring
Pull the wires from the service disconnect
into the switchgear area running at least
12” (300mm) of wiring into the interior.
Connect the wires to the terminal block,
according to the wiring diagram inside the
service hatch. Also see section Wire and
Commission in this document.
To achieve the NEMA 3R rating, the
conduit must be fitted correctly into the
supplied fittings.
Check that the conduit is pressed firmly
into the flex adapters, and the locking
ring is secure.
Underground conduit and wiring