Technical data
Proline t-mass 65 PROFIBUS DP/PA
120
Hauser
Ball valve:
CF3M and CF8M
Seal:
PTFE
Installation and removal assembly, ambient pressure
Lower tube section:
1.4404 to EN 10272 and 316/316L to A479
Upper tube section:
1.4404 to EN 10216-5 and 316/316L to A312
Ball valve:
CF3M and CF8M
Seal:
PTFE
Process connections
For both the flanged and insertion meters it is possible to have wetted parts degreased for
oxygen service. Further information is available from your Hauser sales center.
t-mass F:
Flanges according EN 1092-1, JIS B2220 and ASME B16.5
t-mass I:
G 1A or 1" MNPT thread
11.11 Operability
Display elements
• Liquid crystal display: illuminated, two lines with 16 characters per line
• Selectable display of different measured values and status variables
• At ambient temperatures below –20 °C (–4 °F) the readability of the display may be
impaired.
Operating elements
• Local operation with three keys (
S
,
O
,
F
)
• Quick Setup menus for straight forward commissioning
Languages
English, German, French, Spanish, Italian, Dutch, Norwegian, Finnish, Swedish, Portuguese,
Polish, Czech
11.12 Certificates and approvals
CE mark
The measuring system is in conformity with the statutory requirements of the applicable EC
Directives. These are listed in the corresponding EC Declaration of Conformity along with the
standards applied.
Hauser confirms successful testing of the device by affixing to it the CE mark.
C-Tick mark
The measuring system meets the EMC requirements of the Australian Communications and
Media Authority (ACMA).