Micropilot M FMR250 FOUNDATION Fieldbus
Technical data
Hauser
89
10.1.3
Data of the FOUNDATION Fieldbus interface
Basic Data
Virtual communication
references (VCRs)
Link Settings
Transducer Blocks
Device Type
100F (hex)
Device Revision
05 (hex)
DD Revision
01 (hex)
CFF Revision
01 (hex)
ITK Version
5.0
ITK-Certification Driver-No.
IT042000
Link Master (LAS) cabable
yes
Link Master / Basic Device
selectable
yes; Default: Basic Device
Number VCRs
24
Number of Link-Objects in VFD
24
Permanent Entries
1
Client VCRs
0
Server VCRs
24
Source VCRs
23
Sink VCRs
0
Subscriber VCRs
23
Publisher VCRs
23
Slot time
4
Min. Inter PDU delay
4
Max. response delay
10
Block
Content
Output values
Sensor Block
contains all parameters related to the mesurement
• level or volume
1)
(channel 1)
• distance (channel 2)
1)
je nach Konfiguration des Sensor-Blocks
Diagnsotic Block contains diagnostic information
no output values
Display Block
contains parameters to configure the local display
no output values