Function "full calibr." (006)
This function is used to enter the distance from the minimum level to the maximum level (=span).
In principle, it is possible to measure up to the tip of the antenna. However, due to considerations
regarding corrosion and build-up, the end of the measuring range should not be chosen any closer
than 50 mm (1.97 in) to the tip of the antenna.
L00-FMR2xxxx-14-00-06-en-009
!
Note!
If
bypass
or
stilling well
was selected in the "
tank shape
"
(002)
function, the pipe diameter is
requested in the following step.
Function "pipe diameter" (007)
This function is used to enter the pipe diameter of the stilling well or bypass pipe.
L00-FMR2xxxx-14-00-00-en-011
Microwaves propagate more slowly in pipes than in free space. This effect depends on the inside
diameter of the pipe and is automatically taken into account by the Micropilot. It is only necessary
to enter the pipe diameter for applications in a bypass or stilling well.
⇒