10
Technical data
10.1
Technical data at a glance
10.1.1
Application
The measuring device is for measuring the mass flow and volume flow of liquids in sealed piping
systems. Fluids with widely differing properties can be measured, for example:
• Additives
• Oils, fats
• Acids, alkalis
• Varnishes, paints
• Suspensions
10.1.2
Function and system design
Measuring principle
Mass flow measurement by the Coriolis principle
Measuring system
The measuring system comprises a compact unit consisting of a sensor and transmitter.
10.1.3
Input
Measured variable
• Mass flow
• Volume flow (calculated from mass flow and density)
• Density
• Fluid temperature (measured with temperature sensors)
Measuring range
Recommended full scale values:
See information on
36 ("Limiting flow")
Operable flow range
Greater than 1000:1
Flows above the preset full scale value do not overload the amplifier, i.e. totalizer values are
registered correctly.
DN
Range for full scale values (liquids)
g
min
to
g
max
[mm]
[inch]
[kg/h]
[lb/min]
08
3/8"
0 to 2000
0 to 74
15
½"
0 to 6500
0 to 239
25
1"
0 to 18 000
0 to 662