![Empire DVCD32FP3-2 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/empire/dvcd32fp3-2/dvcd32fp3-2_installation-instructions-and-owners-manual_2403718007.webp)
36167-1-0316
Page 7
CEILING FIRE STOP
90° ELBOW
90° ELBOW
OR
45° ELBOW
WALL STRAP
PIPE LENGTH
WALL THIMBLE
HORIZONTAL
TERMINATION
(MAXIMUM OF
THREE 90° ELBOWS)
VERTICAL
TERMINATION
(MAXIMUM OF
THREE 90° ELBOWS)
STORM COLLAR
ROOF FLASHING
figure 2
vENT SYSTEM IDENTIfICATION
SpECIAL vENT SYSTEMS
Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if
the fireplace is to be vented out the top.
Special venting components
See empire Comfort Systems Retail Price List for Simpson Duravent part
numbers and pricing.
Special DV Vent Kits
Available from empire Comfort Systems Dealers
dvvK-4vP
Direct-Vent Fireplace Vent Kit - Vertical, Includes
46DVA-VCH, 46DVA-F6 and 46DVA-SC
dvvK-4TP
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall,
8 to 11 inch wall thickness, Includes 46DVA-HC,
46DVA-e90, 46DVA-09, 46DVA-08A and 46DVA-WT
DVVK-4RP
Direct-Vent Fireplace Vent Kit for Rear Vent, 5 to 7 inch wall
thickness, (standard thru-the-wall venting) includes
46DVA-06, 46DVA-HC and 46DVA-WT
DVVK-4Re
Direct-Vent Fireplace Vent Kit For Rear Vent, Thru-the-wall
for 5 to 13 3/4 inch wall thickness.
dvvK-4TSP
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall,
5 to 7 inch wall thickness, Includes 46DVA-HC, 46DVA-e90,
46DVA-06 and 46DVA-WT
dvvK-4fv
Vertical Flex Vent Kit 4 x 7
inch
VIB6A
Vertical Inlet Baffle Kit For 6-5/8
inch
diameter.
VIB7A
Vertical Inlet Baffle Kit For 7
inch
diameter.
NOTICE:
Additional pipe may be required for proper venting.
The following 4 x 6-5/8
inch
vent systems are acceptable for use
ith the DVCD(32,36,42)FP series fireplaces:
Simpson Duravent® GS
American metal Products
Selkirk Direct-Temp®
Security Secure Vent®
excel DV Venting
metal Fab
BDm
empire Horizontal Round Termination Kit DVVK-4Re
empire Flexvent Kit DVVK-4F
empire Flexvent Kit DVVK-4FV Vertical Flex Vent Kit
Determine how the vent system will be terminated out the side
of the house or through the roof. Verify the clearances for the
termination.
Содержание DVCD32FP3-2
Страница 41: ...36167 1 0316 Page 41 1 Place Log A on the left front pin of the burner LOG PLACEMENT for DVCD32 fireplaces ...
Страница 42: ...36167 1 0316 Page 42 2 Place Log B on the right front pin of the burner LOG PLACEMENT for DVCD32 fireplaces ...
Страница 44: ...36167 1 0316 Page 44 4 Place Log D onto the rear log support LOG PLACEMENT for DVCD32 fireplaces ...
Страница 48: ...36167 1 0316 Page 48 Log placement is complete LOG PLACEMENT for DVCD32 fireplaces ...
Страница 51: ...36167 1 0316 Page 51 1 Place Log A on the left front pin of the burner LOG PLACEMENT For DVCD36 fireplaces ...
Страница 52: ...36167 1 0316 Page 52 2 Place Log B on the right front pin of the burner LOG PLACEMENT For DVCD36 fireplaces ...
Страница 54: ...36167 1 0316 Page 54 4 Place Log D onto the rear log support LOG PLACEMENT For DVCD36 fireplaces ...
Страница 57: ...36167 1 0316 Page 57 Log placement is complete LOG PLACEMENT For DVCD36 fireplaces ...
Страница 60: ...36167 1 0316 Page 60 1 Place Log A on the left front pin of the burner LOG PLACEMENT for DVCD42 fireplaces ...
Страница 61: ...36167 1 0316 Page 61 2 Place Log B on the right front pin of the burner LOG PLACEMENT for DVCD42 fireplaces ...
Страница 62: ...36167 1 0316 Page 62 3 Place Log D onto the rear log support LOG PLACEMENT for DVCD42 fireplaces ...
Страница 67: ...36167 1 0316 Page 67 Log placement is complete LOG PLACEMENT for DVCD42 fireplaces ...