7.9 CHRONOMETER Parameters
Input Type and Function Selection for Chronometer
Period measurement of signals in Ch-A input
Pulse time measurement of signals in Ch-A input
Sum of the time difference between Ch-A and Ch-B inputs rising edges
For details on parameters, refer to Section 8 (Program Parameters).
SET2
SET1
SET value for Output-1. Control of the Output-1 is done
according to this value. It can be changed by time unit and
scale selection parameter
SET value for Output-2. Control of the Output-2 is done
according to this value. It can be changed by time unit and
scale selection parameter
Second
It can be adjusted from to
Minute
It can be adjusted from to
Hour
It can be adjusted from to
Hour / Minute
It can be adjusted from to
Second / Millisecond
It can be adjusted from to
Minute / Second
It can be adjusted from to
Hour / Minute
It can be adjusted from to
Time Unit and Scale Selection
In operation with Manual or Automatic Reset, at the end of the reset operation, if
counting direction parameter is (0
Þ
P
), count value
becomes . If is (P
Þ0
),count value becomes SET2.
Pulse Time of Ch-A, Ch-B, Reset and Pause Inputs
It is used to protect against the electrical contact debounce or the signal that
is less than the determined pulse time.
It can be adjusted from to msec . If it’s adjusted to
then there is no time protection for Ch-A and Ch-B. If the parameter
value is adjusted or then Reset and Pause protection
times are accepted as 2 msec.