How it operates in BATCH COUNTER function is explained below:
Manual Reset
Output Functions for BATCH COUNTER
Counting direction : 0
Þ
P (Counting to upwards)
=
Reset
SET2
Count
Value
Ch-A
SET1
Batch
Value
Output-1
Output-1
Output-2
0
0
=
=
=
When count value reaches to SET2 value, count value is reset and
Output-2 becomes active.If Output-2 pulse time is
Then Output-2 does not change position until manual reset input is
active. If Output-2 pulse time is not 0, Output-2 becomes
inactive at the end of the pulse time.
When Output-2 becomes active, batch count value is added 1(Batch
count value can be observed by pressing SET1 button). When number
of how many times Output-2 is active becomes equal to SET-1 value,
then Output-1 becomes active. If Output-1 pulse time is
, then Output-1 does not change position until manual reset
input is active. If Output-1 pulse time is not, then Output-1
becomes inactive at the end of the pulse time.