74
How it operates in COUNTER / “TOTALIZER COUNTER”, TIMER
and CHRONOMETER functions is explained below:
Counting direction : P
Þ
0 (Downcount)
=
Set1
0
Output-1
Set2
Reset
Output-1
Output-2
=
=
=
=
Or
When the count value reaches to SET1 value, Output-1 becomes
active. If Output-1 pulse time is , Output-1 does
not change position until manual reset input is active. If Output-1 pulse
time is not 0, Output-1 becomes inactive at the end of the
pulse time.
When the count value reaches to SET2 value, Output-2 becomes
active. Counting does not continue over SET2 value. For starting to
count manual reset input must be active. Output-2 Pulse Time
Is not considered.
Count value is added to total count value when manual reset is active in
COUNTER / “TOTALIZER COUNTER” functions.
When the count value reaches to SET1 value, Output-1 becomes
active. If Output-1 pulse time is , Output-1 does not
change condition until manual reset input is active. If Output-1 pulse
time is not 0, Output-1 becomes inactive at the end of the
pulse time.
When the count value reaches to value, Output-2 becomes
active. Counting does not continue under . For starting to
count manual reset input must be active. Output-2 pulse time
Is not considered.
Count value is added to total count value when manual reset is active in
COUNTER / “TOTALIZER COUNTER” functions.