background image

 

1

H8CA-S

  Solid-State Counter/Timer

 

1/16 DIN, Easy-to-Operate 
Combination Counter and Timer

 

 

Operation selectable as preset counter 
or timer

 

 

6-digit LCD display—
Present Value: 8 mm (0.32 in)
Set Value: 4 mm (0.16 in)

 

 

Nonsignificant zeros suppressible from 
preset or count value display

 

 

Selectable power supply voltages 
24 to 240 VAC and 12 to 120 VDC

 

 

Memory protection

 

 

4 programmable output modes available for 
both counter and timer functions

 

Ordering Information

 

 

Counter/Timer

 

Note:

 

Do not use the contact input at a counting speed of 1 kcps.

Mounting style

Surface/flush mounting

Operating function

Preset counter/timer (selectable)

Operating system (mode)

Counter: reversible (Three input modes and four operating modes are selectable)
Timer: time-limit operation, integrating operation (Four operating modes are 
selectable)

Backup power supply for memory protection

Provided: Approx. 10 years at 20° C (68° F)

Number of counts

0  to 999999 (6 digits)

Timing ranges

0.00 to 9999.99 s, 0.0 to 99999.9 min., 0.0 to 99999.9 h (6 digits)

External connection

Socket

Display type

6-digit backlit LCD; 8 mm (0.32 in) Present Value, 4 mm (0.16 in) Set Value

Count and reset input for counter function; 
reset and gate input for timer function

No-voltage input (See Note.)
(solid-state/contact input)

Voltage input

Control output

Contact

Solid-state

Contact

Solid-state

Power supply/
counting speed

AC

30 cps

 

H8CA-SAL

H8CA-SALS

H8CA-SALV

H8CA-SALVS

 

1 kcps

 

H8CA-SAH

H8CA-SAHS

H8CA-SAHV

H8CA-SAHVS

 

DC

30 cps

 

H8CA-SDL

H8CA-SDLS

H8CA-SDLV

H8CA-SDLVS

 

1 kcps

 

H8CA-SDH

H8CA-SDHS

H8CA-SDHV

H8CA-SDHVS

Содержание H8CA-S Series

Страница 1: ...input modes and four operating modes are selectable Timer time limit operation integrating operation Four operating modes are selectable Backup power supply for memory protection Provided Approx 10 y...

Страница 2: ...60 Hz DC 12 to 120 VDC 20 max permissible ripple Operating voltage range 90 to 110 of rated voltage Power consumption See Note 1 Approx 2 2 VA at 240 VAC 50 Hz Approx 1 W at 120 VDC Max counting spee...

Страница 3: ...bration Mechanical durability 10 to 55 Hz 0 75 mm 0 030 in double amplitude Malfunction durability 10 to 55 Hz 0 3 mm 0 012 in double amplitude Shock Mechanical durability approx 30 G Malfunction dura...

Страница 4: ...ted if the minimums for A and B are not met In Counter Function Mode In Timer Function Mode Command Input Mode A Individual Input Mode B Phase Difference Input Mode C Count input 1 Count input 2 Digit...

Страница 5: ...ne when phase of count input 2 CP2 is delayed with respect to phase of count input 1 CP1 The count value is decreased by one when phase of count input 2 CP2 is ahead with respect to phase of count inp...

Страница 6: ...03 13 6 0 54 78 3 07 50 1 97 45 1 77 45 1 77 50 1 97 Note Recommended panel thickness is 1 to 3 2 mm Panel cutout conforms to DIN 43700 70 max 2 76 7 8 0 31 Eleven M3 5 x 7 5 sems 50 max 1 97 3 0 12...

Страница 7: ...8 0 31 91 9 3 62 Panel Adapter for panel mounting Y92F 30 P3GA 11 back connecting socket 4 5 0 18 L 15 25 25 25 25 1 0 04 27 0 15 35 0 3 7 3 0 15 10 10 L Length 1 m PFP 100N 50 cm PFP 50N 1 m PFP 100...

Страница 8: ...it The function input mode or output mode display will be blinking The Power OFF display will stop blinking when power comes ON Output display Input mode display Output mode display Reset key Advance...

Страница 9: ...e N will stop blinking Always disconnect terminals 1 and 3 when finished selecting the function Values cannot be preset if terminals 1 and 3 are con nected 2 Selecting the timer function with sec and...

Страница 10: ...r the power supply is ON or OFF Press the key until the desired digit begins blinking Press the key to set the desired value Continue pressing the and keys until the smallest digit has been set To com...

Страница 11: ...C voltage is recommended when the counter is installed at a location where the input terminals are easily accessible Note When connecting external signal input contacts and tran sistors use a power su...

Страница 12: ...ol output used as shown in the table below Reset Input Connection Voltage Input Type Type of control output Max counting speed of rated time Output delay time Contact output 30 cps Common to hours min...

Страница 13: ...nput 2 Counts when turned ON Input 1 Input 2 Counts when turned ON Input 2 Input 1 A count signal is input when turned ON 30 VDC max 30 VDC max Input 1 Input 2 A count signal is input when turned OFF...

Страница 14: ...n a signal will be output when the new value is the same as the displayed value The front panel keys operate at a touch Do not press the keys with excessive force or tools such as a screwdriver Press...

Страница 15: ...Y92F 30 adapter loosen the two screws of the adapter pry up the top and bottom hooks of the adapter and pull the H8CA S out from the front of the panel Caution The H8CA S has a built in lithium batter...

Отзывы: