background image

CSM_H8BM-R_DS_E_5_4

1

Multi-maintenance Counter/Timer (DIN 72 x 72) 

H8BM-R

Nine Built-in Counters/Timers to 
Measure Equipment Operating 
Cycles and Times and Forecast 
Maintenance Timing

• Provides up to nine counters or accumulative timers. (Counter and 

timer functions can be used at the same time.)

• Individual forecast outputs to indicate maintenance timing.

• Pre-forecast display and machine stoppage output provided.

• IP54 oil-proof type at setting area for resistance to oil and water.

• Separate digit keys to easily change settings.

• Compact, short-body: 72 

×

 72 

×

 79 mm (DIN).

• Key protection function prevents incorrect operation.

• Multiple outputs: NPN/PNP.

• Directly connectable to 2-wire DC sensors.

• Complies with UL and CSA.

Ordering Information

Multi-maintenance Counter/Timer

Accessories (Order Separately)

Note 1. A Hard Protective Cover and Rubber Packing are supplied with the 

Counter.

2. The H8BM-R

@

 is provided with short input as standard to achieve a 

Multi-stage Counter without having to use a short-circuit plate and 
external wiring.

Specifications

The H8BM-R can be used as a multi-stage preset counter.

Refer to 

Safety Precautions

 on page 7.

For the most recent information on models that have been certified for 
safety standards, refer to your OMRON website.

Preset stage

Nameplate lettering

Model

3-stage setting

Japanese

H8BM-RA DC24

English 

H8BM-RB DC24

1-stage setting

Japanese

H8BM-RAD DC24

English

H8BM-RBD DC24

Name

Model

Hard Protective Cover (See note 1.)

Y92A-72C

Rubber Packing (See note 1.)

Y92S-25

Short-circuit plate (See note 2.)

Y92S-26

Item

Model

H8BM-RA/RB

H8BM-RAD/RBD

Classification

3-stage setting

1-stage setting

Mounting method

Flush mounting

External connections

Screw terminals

Degree of protection

IP54 oil-proof type (case front)

Input mode

Up

Output mode

F mode (Operation continues even when setting is reached.)

Reset system

External, manual resets

Timer operation

Yes

Input method

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O 
inhibit)

Control output

No-contact outputs: RUN, forecast, machine 
stoppage

No-contact outputs: RUN, forecast

Display

Count, preset value, counter number, and error codes displayed on 7-segment LCD
Mode, reset, I/O inhibit, re-monitor modes, and key protection displayed on LCD characters 
Output indication on LCD characters and LEDs

LCD with backlight

Yes

Built-in counter number

9 (counters 1 to 9) (See note 1.)

Preset stage

3-stage (See note 2.)

1-stage (See note 3.)

Digits

Forecast value: 6 digits (999999)
Pre-forecast value: 

5 digits (See note 4.)

Machine stoppage: +5 digits (See note 5.)

Forecast value: 6 digits (999999)

Time ranges

Forecast value: 99999.9 h (0.1 h or longer)/
99999.9 s (0.1 s or longer)
Pre-forecast value:

 −

9999.9 h/

9999.9 s (See 

note 4.)
Machine stoppage: +9999.9 h/+9999.9 s (See 
note 5.)

Forecast value: 99999.9 h (0.1 h or 
longer)/99999.9 s (0.1 s or longer)

Memory backup

EEPROM (Data can be written 100,000 times.), Backup time for power interruption: Approx. 
10 years 

Note 1. Each channel operates on a separate 

I/O.

2. The 3-stage are pre-forecast, forecast, 

and machine stoppage. 

Pre-forecast:

Displayed only on LCD (no 
external output is provided).

Forecast: Displayed on LCD and LED 

and output (output for each 
counter).

Machine stoppage: 

Displayed on LCD and LED 
and output
(output when the count 
value of one or more of 
counters 1 to 9 has reached 
its machine stoppage 
value).

3. This Counter operates on the forecast 

value only.

4. The pre-forecast value is set as a 

negative offset in respect to the 
forecast value.

5. The machine stoppage value is set as 

a positive offset in respect to the 
forecast value.

Содержание H8BM-R Series

Страница 1: ...terminals Degree of protection IP54 oil proof type case front Input mode Up Output mode F mode Operation continues even when setting is reached Reset system External manual resets Timer operation Yes...

Страница 2: ...ying metal parts Dielectric strength voltage 1 000 VAC 50 60 Hz for 1 min between current carrying terminals and exposed non current carrying metal parts Impulse withstand voltage 1 kV between power t...

Страница 3: ...hts Forecast 9 outputs Each of these outputs turns ON when its forecast value has been reached When a total counter is used output one shot signals as carry signals Retain outputs until count values a...

Страница 4: ...OM 8 9 10 11 12 13 14 RUN output Machine stoppage output Forecast output 1 Forecast output 2 Forecast output 3 Forecast output 4 Forecast output 5 1 2 3 4 5 6 7 Power supply 0 V Power supply 24 V Fore...

Страница 5: ...ndicators light to show that the count value has reached the preset value and that the output has turned ON Time Range Indicator s seconds h hours I O Inhibit Indicator Indicates that the I O inhibit...

Страница 6: ...cutout is as shown below according to DIN 43700 The mounting panel thickness must be 1 to 5 mm Mount the Counter so that the ambient temperature will not exceed 55 C Spacing with Other Devices Provide...

Страница 7: ...s of the same size and type can be inserted into a single terminal 17 Separate the input devices input wiring and Counter as far as possible from sources of noise and power lines carrying noise 18 The...

Страница 8: ...e 23456 3 200000 23456 3 200000 23456 3 500 23456 3 10000 Normal Mode Key Press for 4 s min Press for 4 s min This mode is for the operational state The present value set value counter number and outp...

Страница 9: ...to pre forecast value mode is automatically displayed 2 Press the Key or turn ON the counter number selection input to select the counter whose data is to be set or changed Next press the Key to set...

Страница 10: ...modes except initial setting mode and re monitor mode 2 Press the Key or turn ON the reset input to reset the count value to 0 for that counter only 2 Resetting of All Counters at the Same Time Press...

Страница 11: ...ET Key protection is to be set Press the Key to enter the setting Note 1 The Reset of All Counters and All Clear using the RESET Key are disabled if the RESET Key Protection function is turned ON 2 Ke...

Страница 12: ...eset input turns ON the re monitor value will flash 3 times and the only the count value for that counter will be returned to the value prior to being reset The following displays are made when errors...

Страница 13: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Отзывы: