background image

H8BM-R

3

Connections

Internal Connections

I/O Functions

Inputs

Outputs

Note: The input and output signals are enabled when power is applied to the Counter. During a power failure, the input signals are disabled, and the output signals are 

turned OFF.

Count 9 inputs

Input count values.

Used as time count input signal when timer is used.

Max. counting speed receivable: Count inputs 1 to 7: 30 Hz (Min. signal input width: 16.7 ms), Count inputs 8 and 9: 30 Hz/500 Hz 
(Min. signal input width: 16.7 ms/1 ms)

Reset 1 input

Resets count/time value of a displayed Counter No.

Counter under reset does not operate as its output is turned OFF.

Reset signal input received while re-monitor function is ON restores reset count/time value of the specified counter.

While reset signal is ON, RESET indicator lights.

Short

When the short input is ON, an input is also received for one of the count inputs 2 to 9 when an input is received for count input 1. The 
H8BM can thus be used as a multi-stage preset counter without performing external short-circuit wiring.

Counter No. selection

Specifies counter whose count/time value is to be displayed.

I/O inhibit

Inhibits count inputs of all counters.

Turns OFF all forecast outputs, RUN outputs, and machine stoppage outputs.

While I/O inhibit signal is ON, INHB indicator lights.

Forecast 9 outputs

Each of these outputs turns ON when its forecast value has been reached.

When a total counter is used, output one-shot signals as carry signals.

Retain outputs until count values are reset.

RUN 1 output

Turns ON when Counter is operating normally.

Machine stoppage 
1 output (Common)

Turns ON when count value of one counter has reached set machine stoppage value.

Retains output until count value is reset.

Co

u

nt inp

u

t 1

Co

u

nt inp

u

t 2

Co

u

nt inp

u

t 3

Co

u

nt inp

u

t 4

Co

u

nt inp

u

t 5

Co

u

nt inp

u

t 6

Co

u

nt inp

u

t 7

Co

u

nt inp

u

8

Co

u

nt inp

u

t 9

Co

u

nter 

N

o. selection

Reset inp

u

t

I/O inhi

b

it inp

u

t

Short inp

u

t

Inp

u

t COM

OR

16 to 26.4 

V

DC

Forecast o

u

tp

u

t 1

Forecast o

u

tp

u

t 2

Forecast o

u

tp

u

t 3

Forecast o

u

tp

u

t 4

Forecast o

u

tp

u

t 5

Forecast o

u

tp

u

t 6

Forecast o

u

tp

u

t 7

Forecast o

u

tp

u

8

Forecast o

u

tp

u

t 9

Machine 

stoppage o

u

tp

u

t

RU

N

 o

u

tp

u

t

O

u

tp

u

t COM

+24 

V

V

(24 

V

DC

+10

%

 

15

%

)

24

25

26

27

2

8

17

1

8

19

20

23

22

16

15

21

10

11

12

13

14

3

4

5

6

9

8

7

2

1

OR

Load

Load

Load

Load

Load

Load

Load

Load

Load

Load

Load

H8BM-R

Note 1. H8BM-RAD/-RBD outputs the forecast and machine stoppage values simultaneously.

2. The I/O terminals are used for both PNP and NPN. There is no polarity. 

Note 1. When the load is short-circuited, the internal 

circuits may be damaged.

2. Connect a diode to suppress Counter surge when 

an inductive load is connected.

RUN, machine stoppage,
forecast 1 to 9

Output method

Open collector

Switching capacity

30 VDC max., 100 mA max.

Residual voltage

2 VDC max.

Leakage current

100 

μ

A max.

Содержание H8BM-R Series

Страница 1: ...terminals Degree of protection IP54 oil proof type case front Input mode Up Output mode F mode Operation continues even when setting is reached Reset system External manual resets Timer operation Yes...

Страница 2: ...ying metal parts Dielectric strength voltage 1 000 VAC 50 60 Hz for 1 min between current carrying terminals and exposed non current carrying metal parts Impulse withstand voltage 1 kV between power t...

Страница 3: ...hts Forecast 9 outputs Each of these outputs turns ON when its forecast value has been reached When a total counter is used output one shot signals as carry signals Retain outputs until count values a...

Страница 4: ...OM 8 9 10 11 12 13 14 RUN output Machine stoppage output Forecast output 1 Forecast output 2 Forecast output 3 Forecast output 4 Forecast output 5 1 2 3 4 5 6 7 Power supply 0 V Power supply 24 V Fore...

Страница 5: ...ndicators light to show that the count value has reached the preset value and that the output has turned ON Time Range Indicator s seconds h hours I O Inhibit Indicator Indicates that the I O inhibit...

Страница 6: ...cutout is as shown below according to DIN 43700 The mounting panel thickness must be 1 to 5 mm Mount the Counter so that the ambient temperature will not exceed 55 C Spacing with Other Devices Provide...

Страница 7: ...s of the same size and type can be inserted into a single terminal 17 Separate the input devices input wiring and Counter as far as possible from sources of noise and power lines carrying noise 18 The...

Страница 8: ...e 23456 3 200000 23456 3 200000 23456 3 500 23456 3 10000 Normal Mode Key Press for 4 s min Press for 4 s min This mode is for the operational state The present value set value counter number and outp...

Страница 9: ...to pre forecast value mode is automatically displayed 2 Press the Key or turn ON the counter number selection input to select the counter whose data is to be set or changed Next press the Key to set...

Страница 10: ...modes except initial setting mode and re monitor mode 2 Press the Key or turn ON the reset input to reset the count value to 0 for that counter only 2 Resetting of All Counters at the Same Time Press...

Страница 11: ...ET Key protection is to be set Press the Key to enter the setting Note 1 The Reset of All Counters and All Clear using the RESET Key are disabled if the RESET Key Protection function is turned ON 2 Ke...

Страница 12: ...eset input turns ON the re monitor value will flash 3 times and the only the count value for that counter will be returned to the value prior to being reset The following displays are made when errors...

Страница 13: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Отзывы: