8

Operation

Key protection and whether each counter operates as a counter or a timer are specified on a DIP switch provided on the side panel of the 

Counter. Open the cover of the switch compartment on the side of the Counter to access the DIP switch.

The system will always enter the RUN mode after the power supply is turned ON. 

1. DIP Switch Settings

5

4

3

2

1

6

7

8

9 10

Timer

Co

u

nter

Ena

b

led

Disa

b

led

Key Protection
(Can al

w

ays 

b

e s

w

itched.)

DIP s

w

itch compartment

Note 1. Set the DIP switch (except for Key Protection) before turning 

ON the power.
Changes to DIP switch settings while the Counter is operating 
will be ignored. Power must be turned OFF then back ON 
after changing the settings. 
Changes to DIP switch settings are also enabled when 
changing to initial setting mode because the same operation 
is performed as when cycling the power.

2. Key protection can be set for each key. Key protection will be 

performed based on the details set in the initial setting mode. 
Refer to 

Initial Setting Mode

 on page 11.

2. Changing Mode

MODE  Key 

MODE 

MODE  Key 

MODE  Key 

MODE  Key 

Key 

Re-monitor mode 

Refer to page 11 for  
information on the initial  
setting mode.  

-- 

23456 

200000 

23456 

200000 

23456 

500 

23456 

10000 

N

ormal Mode  

Key 

Press for 4 s min. 

Press for 4 s min. 

This mode is for the operational state. 
The present 

v

al

u

e, set 

v

al

u

e, co

u

nter n

u

m

b

er, 

and o

u

tp

u

t stat

u

w

ill 

b

e displayed.  

This mode is for setting forecast 

v

al

u

es. 

V

al

u

es can 

b

e independently set for each 

co

u

nter n

u

m

b

er. 

This mode is for setting pre-forecast 

v

al

u

es. 

The pre-forecast 

w

ill 

b

e displayed (LCD) as a 

v

al

u

b

efore 

the forecast 

v

al

u

e. Set that 

v

al

u

e as the pre-forecast 

v

al

u

e. 

V

al

u

es can 

b

e independently set for each co

u

nter n

u

m

b

er. 

Set the pre-forecast 

v

al

u

b

y de

v

iation.

RU

N

 mode 

Forecast 

v

al

u

e mode 

Pre-forecast 

v

al

u

e mode* 

Machine stoppage mode* 

Initial Setting Mode 

SET 

Refer to page 12 for 
information on the 
re-monitor mode.  

This mode is for setting machine stoppage 

v

al

u

es. 

Machine stoppage (o

u

tp

u

t/LCD) 

w

ill occ

u

r at a 

v

al

u

e in 

excess of the forecast 

v

al

u

e. Set that 

v

al

u

e as the 

machine stoppage 

v

al

u

e.  

V

al

u

es can 

b

e independently set for each co

u

nter n

u

m

b

er, 

bu

t machine stoppage o

u

tp

u

w

ill 

b

e performed if any 

co

u

nter from 

N

o. 1 to 9 reaches the machine stoppage 

v

al

u

e. Set the machine stoppage 

v

al

u

b

y de

v

iation.  

Note: I/O operations are always performed regardless 

of the mode.
If no key is pressed for 1 minute in each mode, 
the RUN mode is automatically restored.

 will flash.

The modes marked * are not provided on the 1-

stage type Counter.

3

Содержание H8BM-R Series

Страница 1: ...terminals Degree of protection IP54 oil proof type case front Input mode Up Output mode F mode Operation continues even when setting is reached Reset system External manual resets Timer operation Yes...

Страница 2: ...ying metal parts Dielectric strength voltage 1 000 VAC 50 60 Hz for 1 min between current carrying terminals and exposed non current carrying metal parts Impulse withstand voltage 1 kV between power t...

Страница 3: ...hts Forecast 9 outputs Each of these outputs turns ON when its forecast value has been reached When a total counter is used output one shot signals as carry signals Retain outputs until count values a...

Страница 4: ...OM 8 9 10 11 12 13 14 RUN output Machine stoppage output Forecast output 1 Forecast output 2 Forecast output 3 Forecast output 4 Forecast output 5 1 2 3 4 5 6 7 Power supply 0 V Power supply 24 V Fore...

Страница 5: ...ndicators light to show that the count value has reached the preset value and that the output has turned ON Time Range Indicator s seconds h hours I O Inhibit Indicator Indicates that the I O inhibit...

Страница 6: ...cutout is as shown below according to DIN 43700 The mounting panel thickness must be 1 to 5 mm Mount the Counter so that the ambient temperature will not exceed 55 C Spacing with Other Devices Provide...

Страница 7: ...s of the same size and type can be inserted into a single terminal 17 Separate the input devices input wiring and Counter as far as possible from sources of noise and power lines carrying noise 18 The...

Страница 8: ...e 23456 3 200000 23456 3 200000 23456 3 500 23456 3 10000 Normal Mode Key Press for 4 s min Press for 4 s min This mode is for the operational state The present value set value counter number and outp...

Страница 9: ...to pre forecast value mode is automatically displayed 2 Press the Key or turn ON the counter number selection input to select the counter whose data is to be set or changed Next press the Key to set...

Страница 10: ...modes except initial setting mode and re monitor mode 2 Press the Key or turn ON the reset input to reset the count value to 0 for that counter only 2 Resetting of All Counters at the Same Time Press...

Страница 11: ...ET Key protection is to be set Press the Key to enter the setting Note 1 The Reset of All Counters and All Clear using the RESET Key are disabled if the RESET Key Protection function is turned ON 2 Ke...

Страница 12: ...eset input turns ON the re monitor value will flash 3 times and the only the count value for that counter will be returned to the value prior to being reset The following displays are made when errors...

Страница 13: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Отзывы: