Parameter
01.047
Preset Select Flag 3
Short description
Defines which preset is selected by the drive
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
4ms read
Display Format
Standard
Decimal Places
0
Coding
RW, NC
See
Reference Selector
(01.014).
Parameter
01.048
Preset Selector Timer Reset
Short description
Set to 1 to hold the preset selected indicator at 1
Mode
Open
‑
loop
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, NC
See
Preset Selector Timer
(01.016).
Parameter
01.049
Reference Selected Indicator
Short description
Displays which reference is currently selected
Mode
Open
‑
loop
Minimum
1
Maximum
6
Default
Units
Type
8 Bit Volatile
Update Rate
4ms write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT
See
Reference Selector
(01.014).
Parameter
01.050
Preset Selected Indicator
Short description
Displays which preset is currently selected
Mode
Open
‑
loop
Minimum
1
Maximum
8
Default
Units
Type
8 Bit Volatile
Update Rate
4ms write
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT
See
Reference Selector
(01.014).
Parameter
01.051
Power-up Keypad Control Mode Reference
Short description
Defines which value of keypad control mode reference is displayed at power-up
Mode
Open
‑
loop
Minimum
0
Maximum
2
Default
0
Units
Type
8 Bit User Save
Update Rate
Power-up read
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
Description
0
Reset
Keypad reference is zero
1
Last
Keypad reference is the last used value
2
Preset
Keypad reference is copied from Preset speed 1 (01.21)
Power-up Keypad Control Mode Reference
(01.051) defines the value written to
Keypad Control Mode Reference
(01.017) at power-up as given below.
Power-
up Keypad Control Mode Reference
(01.051)
Value wrriten to
Keypad Control Mode Reference
(01.017) at power-up
0
0.0
1
The value in
Keypad Control Mode Reference
(01.017) at the previous power-down
2
The value saved in
Preset Reference 1
(01.021)
26
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
Содержание unidrive m200
Страница 1: ...Parameter Reference Guide Unidrive M200 Open loop Mode Issue 01 05 00 10 ...
Страница 29: ...Menu 2 Frequency Ramps Mode Open loop Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 29 ...
Страница 30: ...30 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Страница 83: ...Enable logic Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 83 ...
Страница 100: ...Menu 7 Analog I O Mode Open loop 100 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Страница 113: ...Menu 8 Digital I O Mode Open loop Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 113 ...
Страница 125: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 125 ...
Страница 144: ...Menu 10 Status and Trips Mode Open loop 144 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...
Страница 145: ...Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 145 ...
Страница 204: ...204 Unidrive M200 Parameter Reference Guide Issue 01 05 00 10 ...