MVS205 Specifications*
DIFFERENTIAL PRESSURE INPUT
Range
: 0 - 250 in H
2
O (0 - 62.2 kPa)
Reference Accuracy:
±
0.075% of span (includes
linearity, hysteresis, and repeatability effects) for
spans up to 10:1 turndown.
Stability:
±
0.1% of upper range limit for 12 months.
STATIC PRESSURE INPUT
Range:
Either Absolute or Gauge:
¨
0 - 800 psia/psig (0 -5516 kPa)
¨
0 - 3626 psia/psig (0 - 25,000 kPa)
Reference Accuracy:
±
0.075% of span (includes
linearity, hysteresis, and repeatability effects) for
spans up to 6:1 turndown.
Stability:
±
0.1% of upper range limit for 12 months.
PROCESS TEMPERATURE INPUT
Type:
For platinum 100-ohm RTD
(conforming to
IEC 751 Class B), with
α
= 0.00385.
Range:
-40 to 400 °C (-40 to 752 °F).
Reference Accuracy:
±0.28 °C (±0.5 °F), exclusive
of RTD sensor error. Specification includes linearity,
hysteresis, and repeatability effects.
Excitation Current:
130
µ
A.
OUTPUT (MVS205R Only)
RS-485 asynchronous-style serial communication
using Fisher protocol for up to 4000-foot distance.
POWER
20 mA dc max. at 8 to 30 Vdc, supplied by FloBoss
or Remote MVS Interface.
ENVIRONMENTAL
Operating Temperature:
-40 to 65 °C (-40 to 149 °F).
Storage Temperature:
-50 to 85 °C (-58 to 185 °F).
Operating Humidity:
0 to 100%.
DIMENSIONS (With Head)
5.8 in. H by 6.4 in. W by 3.3 in. D (147 mm by 163
mm by 84 mm). Head by itself is 3.2 in. H by 6.0
in. W by 3.0 in. D (81 mm by 152 mm by 76 mm).
CONNECTIONS
Conduit:
Head has two 1/2-inch NPT
connections.
Process:
1/4-18 NPT on 2-1/8 inch centers.
CONSTRUCTION
Sensor Body and Coplanar Flange:
316 SST.
Wetted Parts:
316 SST is standard; Hastelloy
(NACE compliant) is available. Wetted O-rings
are glass-filled TFE.
Electronics Head (MVS205R Only):
Urethane-
painted die-cast aluminum alloy, rated Type 4X.
MOUNTING (MVS205R Only)
Pipestand:
Mounts on 2-inch pipe with U-bolt
and optional flange bracket.
Wall/panel:
Mounts with optional flange bracket,
bolted on 2.8 in. centers.
WEIGHT
Including head, 6.7 lb. (3.0 kg).
APPROVALS (MVS205R Only)
Approved by CSA as Models W30248-Series or
RS3-Series for hazardous locations Class I, Divi-
sion 1 (explosion proof), Groups C and D.
Installation requires unarmored RTD cable to
maintain rating.
Approved by Measurement (Industry) Canada for
custody transfer.
*For additional Integral MVS205 specifications, see the FloBoss 407 specifications in Section 2.
Содержание Fisher FLOBOSS 407
Страница 6: ...FloBoss 407 Instruction Manual vi Rev 5 00 This page is intentionally left blank ...
Страница 22: ...FloBoss 407 Instruction Manual 1 16 Rev 5 00 This page intentionally left blank ...
Страница 134: ...FloBoss 407 Instruction Manual 4 24 Rev 5 00 This page is intentionally left blank ...
Страница 160: ...FloBoss 407 Instruction Manual B 4 Rev 5 00 DOC0326A Figure B 4 Pipe Mounting of FloBoss 407 with Integral MVS ...
Страница 184: ...FloBoss 407 Instruction Manual C 8 Rev 5 00 This page is intentionally left blank ...
Страница 190: ...FloBoss 407 Instruction Manual G 6 Rev 5 00 This page is intentionally left blank ...
Страница 199: ...FloBoss 407 Instruction Manual Rev 5 00 I 9 This page intentionally left blank ...