background image

TROUBLESHOOTING

Symptom

Possible Cause

Corrective Action

No Heat/No Cool/No Fan 

(common problems)

1 . Blown fuse or tripped circuit breaker . 

2 . Furnace power switch to OFF . 

3 . Furnace blower compartment door or 

  panel loose or not properly installed . 

4 . Loose connection to thermostat or system .

Replace fuse or reset breaker . 

Turn switch to ON . 

Replace door panel in proper position to engage safety 

interlock or door switch . 

Tighten connections .

No Heat

1 . Pilot light not lit . 

2 . Furnace Lock-Out Condition . Heat 

  may also be intermittent . 

 

 

3 . Heating system requires service or 

  thermostat requires replacement . 

Re-light pilot . 

Many furnaces have safety devices that shut down when 

a lock-out condition occurs . If the heat works intermittently 

contact the furnace manufacturer or local HVAC service 

person for assistance . 

Diagnostic: 

Set SYSTEM Switch to 

HEAT

 and raise the 

setpoint above room temperature . Within a few seconds 

the thermostat should make a soft click sound . This sound 

usually indicates the thermostat is operating properly . If 

the thermostat does not click, try the reset operation listed 

above . If the thermostat does not click after being reset 

contact your heating and cooling service person or place 

of purchase for a replacement . If the thermostat clicks, 

contact the furnace manufacturer or a HVAC service 

person to verify the heating is operating correctly .

No Cool                                   

      

1 . Cooling system requires service or 

  thermostat requires replacement .

Same as diagnostic for No Heat condition except set the 

thermostat to 

COOL

 and lower the setpoint below the 

room temperature . There may be up to a five minute delay 

before the thermostat clicks in Cooling .

Heat, Cool or Fan 

Runs Constantly

1 . Possible short in wiring . 

2 . Possible short in thermostat . 

3 . Possible short in heat/cool/fan system . 

4 . FAN Switch set to Fan 

ON

 .

Check each wire connection to verify they are not shorted 

or touching together . No bare wire should stick out from 

under terminal block . Try resetting the thermostat as de-

scribed above . If the condition persists the manufacturer 

of your system or service person can instruct you on how 

to test the Heat/Cool system for correct operation . If the 

system operates correctly, replace the thermostat .

Thermostat Setting & 

Thermostat Thermometer 

Disagree

1 . Thermostat thermometer setting 

  requires adjustment .

The thermometer can be ad/- 4 degrees . See 

Temperature Display Adjustment in the Configuration 

Menu section .

Furnace (Air Conditioner) 

Cycles Too Fast or Too Slow 

(narrow or wide  

temperature swing)

 

1 . The location of the thermostat and/or 

  the size of the Heating System may 

  be influencing the cycle rate .

Digital thermostats provide precise control and cycle 

faster than older mechanical models . The system turns 

on and off more frequently but runs for a shorter time 

so there is no increase in energy use . If you would like 

an increased cycle time, choose 

SL

 for slow cycle in the 

Configuration menu, step 7 (heat) or 8 (cool) . If an ac-

ceptable cycle rate is not achieved, contact a local HVAC 

service person for additional suggestions . 

Forgot Keypad 

Lockout Code

Press the menu 

key

 (

key

 will disappear) and hold in for 

20 seconds . This unlocks the thermostat .

Blank display any or keypad 

not responding

1 . Voltage Spike or static discharge

Use the Reset Operation shown above .

"Call for Service" on display

Power applied to thermostat "L" terminal

Indicates the heat pump system is sending a signal (volt-

age) to the thermostat terminal marked "L" . It does not 

indicate a malfunction in the thermostat . The manufac-

turer of the Heat Pump system can determine the likely 

cause of 

Call for Service 

on the thermostat by identifying 

the component in the system sending power to the "L" 

terminal .

 

Reset Operation
Note:

 When thermostat is reset, installer configuration menu settings and programming will reset to factory settings . 

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermo-
stat by removing the wires from terminals 

R

 and 

C

 (do not short them together) and removing batteries for 2 minutes . After 

resetting the thermostat, replace the wires and batteries . If the thermostat has been reset and still does not function correctly 
contact your heating/cooling service person or place of purchase . 

Note:

 Be sure to review the installer configuration menu settings . 

To reset the programming, clock and configuration settings,

 press the 

 and 

 and SYSTEM keys simultaneously . The 

thermostat should go blank and then all segments will be displayed momentarily .

14

Содержание 1F95-1280

Страница 1: ... Thermostat Configuration Options Thermostat Applications Maximum Stages Heat Cool W Economizer Max Stage Heat Cool Single Stage 1 No Heat Pump SS1 Gas Oil Electric Heat Only Cool Only or Heat Cool Systems 2 or 3 wire Hydronic Zone Hot Water or Steam Systems 24 Volt or Millivolt 1 1 1 2 Multi Stage 2 No Heat Pump MS2 2 2 2 3 Heat Pump 1 Single Stage Compressor Heat Pump HP1 Single Stage Compressor...

Страница 2: ...he Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch options WARNING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code INSTALLATION Figure 1 Thermostat Base Multi Stage 1F95 1280 2 AA Batteries Power Stealing Switche...

Страница 3: ...gured for Electric Heat Installer Configuration Menu selects O or B for changeover function Set to O terminal energized in Cool mode Set to B terminal energized in Heat emergency mode Power closed connection for SPDT 3 wire zone valve Fault or system malfunction indicator for Heat Pumps with L terminal connection COOLING CLASS II TRANSFORMER HOT 24VAC NEUTRAL 120VAC HEATING 120VAC Dual fuel option...

Страница 4: ...2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 19 2 1 11 10 15 16 9 8 17 13 12 4 18 14 A steady Cool Savings display indicates the feature is enabled in the installer menu A flashing Cool Savings display indicates the feature is active 15 Remote indicates that the indoor remote temperature sensor is being accessed Outdoor Remote indi cates the outdoor remote temperat...

Страница 5: ...s Continuous Display backlight 12 LO dL HI Selects Backlight Intensity 13 0 Temperature 5 LO to 5 HI Selects Adjustable Ambient Temperature Display range 5 LO to 5 HI 14 F C Selects F C Display temperature units in Fahrenheit or Celsius 15 On b OFF Selects audible Beeper On Off 16 On dS OFF Selects Daylight Saving Time calculation 17 On Heat AS OFF Selects Automatic Schedule for comfort temperatur...

Страница 6: ...ctory default setting is fast cycle FA Cr in all modes Heat Cool Emer To change to slow cycling SL Cr press touch keys or toggle between FA SL The cycle rates are below Mode Fast rate Slow rate Heat SS1 MS2 0 6 F 1 5 F Cool SS1 MS2 1 2 F 1 7 F Heat Pump HP1 HP2 1 2 F 1 7 F Emer Heat HP1 HP2 0 6 F 1 7 F 10 Select Compressor Lockout CL Selecting CL On will cause the thermostat to wait 5 minutes betw...

Страница 7: ...tting between 62 F and 98 F Temperature Limit icon will be displayed to the left of your setpoint temperature when using this feature Temperature Limit icon will flash if an attempt is made to adjust the temperature beyond the range selected 23 Cool Temperature Limit Range This feature adjusts the lowest setpoint temperature for cool The default setting is 45 F It can be changed to a setting betwe...

Страница 8: ...eat will not turn on The default setting is 60 but can be set in the range of 5 to 79 INSTALLER CONFIGURATION MENU If indoor temperature drops below 45 because of a pos sible heat pump malfunction the thermostat will turn off the pump and switch to Auxiliary heat Call for Service will display on screen There are two ways the thermostat will return to normal heat pump operation Press any key to ret...

Страница 9: ...below room tempera ture The heating system should stop operating Cooling 1 Press SYSTEM to select COOL 2 Press to adjust the thermostat setting below room tem perature The blower should come on immediately on high speed followed by cold air circulation The display should show System On If the setpoint temperature display is flashing the compressor lockout feature is operating see Configuration men...

Страница 10: ...inutes only in clock display 4 Press and hold either the or touch keys until you reach the correct minutes 5 Press Set Time once again to display year 6 Press either the or touch key until you reach the correct year 7 Press Set Time once again to display month 8 Press either the or touch key until you reach the correct month 9 Press Set Time once again to display date of the month along with day o...

Страница 11: ...gram all the heating temperatures during the day to a comfortable temperature and then lower the temperature 6 at night Auto Schedule Cool will program all of the cooling time periods to the same temperature Note Auto Schedule is available only when the thermostat is first powered on after the thermostat has been reset or anytime you turn AS on in the Configuration Menu item 18 AS Heat or 19 AS Co...

Страница 12: ...cil in your own program times and temperatures The 1F95 1280 comes configured for 7 day programming and can also be configured for 5 1 1 programming see configura tion section Factory settings are listed on Monday Saturday and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a...

Страница 13: ...ration of the thermostat the current tempera ture displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight x local sensor temperature remote sensor weight x remote sensor temperature local sensor weight remote sensor weight Example Local sensor temperature is 80 and the remote sensor is 70 If weight is selected H4 the averaged temperatu...

Страница 14: ...stem operates correctly replace the thermostat Thermostat Setting Thermostat Thermometer Disagree 1 Thermostat thermometer setting requires adjustment The thermometer can be adjusted 4 degrees See Temperature Display Adjustment in the Configuration Menu section Furnace Air Conditioner Cycles Too Fast or Too Slow narrow or wide temperature swing 1 The location of the thermostat and or the size of t...

Страница 15: ...15 NOTES ...

Страница 16: ...White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 www white rodgers com www emersonclimate com ...

Отзывы: