background image

INSTALLER/CONFIGURATION MENU

To enter the menu: Press the

 Menu

 touch key . Press and hold for 5 seconds the 

Installer Config

 touch key . This displays 

screen reference #1 in the table below . Screen Reference numbers appear in top right corner of display . Press 

 to advance 

to the next menu item or 

 to return to a previous menu item . Press   or   to change a menu item option . Shaded items are 

not available if selected for Non-Programmable .

CONFIGURATION MENU

Screen

Reference

Number

SS1

MS2

HP1
HP2 

Press 

key

Displayed 

Factory 

(Default)

Press 

 or 

 

to select from 

listed options

Comments

1

MS 2

HP 1, HP 2, SS 1

Selects Multi-Stage (MS2, No Heat Pump), Heat Pump 1 

 

 (HP1, 1 compressor), Heat Pump 2 (HP2, 2 compressor  

 

 or 2 speed compressor), or Single Stage .

2

(GAS)

ELE

GAS setting: furnace controls blower .  

 

 

 ELE setting: thermostat controls blower .

3

0b (0)

b

Selects Reversing Valve (This item is only to appear if HP1 or HP2 

is selected above .)

4

Days, 

(7) P

5

 or 

0

Programs per week . (7 days, 5-1-1 days or non-programmable)

5

Cool-Off-

Heat-Auto

Cool-Off-Heat, Heat Off, 

Heat, Cool-Off, Auto Off

System switch configuration in non heat pump mode .

Cool-Off-Heat-

Em-Auto

Cool-Off-Heat-Em, 

Off-Em-Auto

System switch configuration, heat pump mode .

6

(On) 

E

OFF

Selects Energy Management Recovery . Not available if 4 is 0

7

(FA) Heat, Cr 

SL

Selects Adjustable Anticipation, cycle rate, Heat

8

(FA) Cool, Cr 

SL

Selects Adjustable Anticipation, cycle rate, Cool

9

(FA) Cr/AU, Em

SL

Selects Adjustable Anticipation, cycle rate auxiliary, (This item is  

 only to appear if HP1 or HP2 is selected above) .

10

(OFF) 

CL

 

On

Selects Compressor Lockout .

11

(On) 

dL

OFF

Selects Continuous Display backlight .

12

(LO) 

dL

HI

Selects Backlight Intensity .

13

0

(Temperature)

5, LO to 5, HI

Selects Adjustable Ambient Temperature Display [range -5 (LO) to 

+5 (HI)] .

14

°F

°C

Selects °F/°C Display (temperature units in Fahrenheit or Celsius) .

15

(On) 

b

OFF

Selects audible Beeper On/Off .

16

(On) 

dS

OFF

Selects Daylight Saving Time calculation .

17

(On) Heat, 

AS

 

OFF

Selects Automatic Schedule for comfort temperature Programming, 

heat mode . Not available if 4 is 0

18

(On) Cool, 

AS

 

OFF

Selects Automatic Schedule for comfort temperature Programming, 

cool mode . Not available if 4 is 0

19

(OFF) 

CS

  

On

Selects Cool Savings Feature On of Off .

20

CS 

Cool Savings

(3)

1-2-3-4-5-6

Selects amount of Cool Savings adjustment .

21

(OFF) 

CO

On

Selects Compressor Optimization (not available on earlier models)

22

(99) Heat, 

HL

 

62-98

TEMPERATURE LIMIT, HEAT (max . heat set point) .

23

(45) Cool, 

LL

 

46-82

TEMPERATURE LIMIT, COOL (min . cool set point) .

24

OFF,   

Keypad Lockout

L

 (total), 

P

 (partial), 

Temperature Limit

(limited temperature range)

Selects Keypad Lockout .

25

000

001-999

Selects Keypad Lockout Combination (active only if keypad Lockout

is selected) .

26

MS2

(On) Heat, FS 

OFF

Fast second stage of heat (not available if SS1 is selected above) .

27

MS2

HP2

(On) Cool, FS 

OFF

Fast second stage of cool (not available if SS1 or HP1 

is selected above) .

28

Remote (OFF)

On

Remote temperature sensor, enable/disable .

29

Remote, In 

Outdoor Remote

Remote temperature sensor (Indoor/Outdoor) .

30

(On) LS

OFF

Local temp . Sensor enable/disable (only when Indoor Remote is   

 selected  On) .

31

(OFF) dF

On

Selects Dual Fuel feature On or OFF (this item appears if HP1 or HP2 

is selected above) .

32

(35) dF

-5 - 50

Selects Dual Fuel setpoint (°F), dF selected On with outdoor sensor 

available .

33

(05) dF

0 - 09

Selects Dual Fuel setting using software logic, dF selected On with no 

outdoor sensor .

5

Содержание 1F95-1280

Страница 1: ... Thermostat Configuration Options Thermostat Applications Maximum Stages Heat Cool W Economizer Max Stage Heat Cool Single Stage 1 No Heat Pump SS1 Gas Oil Electric Heat Only Cool Only or Heat Cool Systems 2 or 3 wire Hydronic Zone Hot Water or Steam Systems 24 Volt or Millivolt 1 1 1 2 Multi Stage 2 No Heat Pump MS2 2 2 2 3 Heat Pump 1 Single Stage Compressor Heat Pump HP1 Single Stage Compressor...

Страница 2: ...he Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch options WARNING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code INSTALLATION Figure 1 Thermostat Base Multi Stage 1F95 1280 2 AA Batteries Power Stealing Switche...

Страница 3: ...gured for Electric Heat Installer Configuration Menu selects O or B for changeover function Set to O terminal energized in Cool mode Set to B terminal energized in Heat emergency mode Power closed connection for SPDT 3 wire zone valve Fault or system malfunction indicator for Heat Pumps with L terminal connection COOLING CLASS II TRANSFORMER HOT 24VAC NEUTRAL 120VAC HEATING 120VAC Dual fuel option...

Страница 4: ...2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 19 2 1 11 10 15 16 9 8 17 13 12 4 18 14 A steady Cool Savings display indicates the feature is enabled in the installer menu A flashing Cool Savings display indicates the feature is active 15 Remote indicates that the indoor remote temperature sensor is being accessed Outdoor Remote indi cates the outdoor remote temperat...

Страница 5: ...s Continuous Display backlight 12 LO dL HI Selects Backlight Intensity 13 0 Temperature 5 LO to 5 HI Selects Adjustable Ambient Temperature Display range 5 LO to 5 HI 14 F C Selects F C Display temperature units in Fahrenheit or Celsius 15 On b OFF Selects audible Beeper On Off 16 On dS OFF Selects Daylight Saving Time calculation 17 On Heat AS OFF Selects Automatic Schedule for comfort temperatur...

Страница 6: ...ctory default setting is fast cycle FA Cr in all modes Heat Cool Emer To change to slow cycling SL Cr press touch keys or toggle between FA SL The cycle rates are below Mode Fast rate Slow rate Heat SS1 MS2 0 6 F 1 5 F Cool SS1 MS2 1 2 F 1 7 F Heat Pump HP1 HP2 1 2 F 1 7 F Emer Heat HP1 HP2 0 6 F 1 7 F 10 Select Compressor Lockout CL Selecting CL On will cause the thermostat to wait 5 minutes betw...

Страница 7: ...tting between 62 F and 98 F Temperature Limit icon will be displayed to the left of your setpoint temperature when using this feature Temperature Limit icon will flash if an attempt is made to adjust the temperature beyond the range selected 23 Cool Temperature Limit Range This feature adjusts the lowest setpoint temperature for cool The default setting is 45 F It can be changed to a setting betwe...

Страница 8: ...eat will not turn on The default setting is 60 but can be set in the range of 5 to 79 INSTALLER CONFIGURATION MENU If indoor temperature drops below 45 because of a pos sible heat pump malfunction the thermostat will turn off the pump and switch to Auxiliary heat Call for Service will display on screen There are two ways the thermostat will return to normal heat pump operation Press any key to ret...

Страница 9: ...below room tempera ture The heating system should stop operating Cooling 1 Press SYSTEM to select COOL 2 Press to adjust the thermostat setting below room tem perature The blower should come on immediately on high speed followed by cold air circulation The display should show System On If the setpoint temperature display is flashing the compressor lockout feature is operating see Configuration men...

Страница 10: ...inutes only in clock display 4 Press and hold either the or touch keys until you reach the correct minutes 5 Press Set Time once again to display year 6 Press either the or touch key until you reach the correct year 7 Press Set Time once again to display month 8 Press either the or touch key until you reach the correct month 9 Press Set Time once again to display date of the month along with day o...

Страница 11: ...gram all the heating temperatures during the day to a comfortable temperature and then lower the temperature 6 at night Auto Schedule Cool will program all of the cooling time periods to the same temperature Note Auto Schedule is available only when the thermostat is first powered on after the thermostat has been reset or anytime you turn AS on in the Configuration Menu item 18 AS Heat or 19 AS Co...

Страница 12: ...cil in your own program times and temperatures The 1F95 1280 comes configured for 7 day programming and can also be configured for 5 1 1 programming see configura tion section Factory settings are listed on Monday Saturday and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a...

Страница 13: ...ration of the thermostat the current tempera ture displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight x local sensor temperature remote sensor weight x remote sensor temperature local sensor weight remote sensor weight Example Local sensor temperature is 80 and the remote sensor is 70 If weight is selected H4 the averaged temperatu...

Страница 14: ...stem operates correctly replace the thermostat Thermostat Setting Thermostat Thermometer Disagree 1 Thermostat thermometer setting requires adjustment The thermometer can be adjusted 4 degrees See Temperature Display Adjustment in the Configuration Menu section Furnace Air Conditioner Cycles Too Fast or Too Slow narrow or wide temperature swing 1 The location of the thermostat and or the size of t...

Страница 15: ...15 NOTES ...

Страница 16: ...White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 www white rodgers com www emersonclimate com ...

Отзывы: