Program Override (Temporary Override)

Press 

 or 

 keys to adjust the temperature . This will over-

ride the temperature setting for a (default) four hour override 
period . The override period can be shortened by pressing   
or lengthened by pressing   . Program Override period can 
range from 15 minutes to 7 days .

Example: 

If you turn up the heat during the morning program, 

it will be automatically lowered later, when the temporary hold 
period ends . To cancel the temporary setting at any time and 
return to the program, press 

Run Schedule

 .

If the SYSTEM key is pressed to select 

AUTO

 the thermostat 

will change to Heat or Cool, whichever ran last . If it switches 
to heat, but you want cool, or it changes to cool, but you want 
heat, press both 

 and 

 keys simultaneously to change to 

the other mode .

OPERATING YOUR THERMOSTAT

Auto: 

Auto Changeover is used in areas where both heating 

and cooling may be required on the same day . 

AUTO

 allows 

the thermostat to automatically select heating or cooling 
depending on the indoor temperature and the selected heat 
and cool temperatures . When using 

AUTO

, be sure to set the 

Cooling temperatures more than 1° Fahrenheit higher than 
the heating temperature .

Manual Operation for

Non-Programmable Mode

Press the SYSTEM key to select Heat or Cool and use the 

 or 

 to adjust the temperature to your desired setting . 

After selecting your desired settings you can also press the 
SYSTEM key to select 

AUTO

 to allow the thermostat to auto-

matically change between Heat and Cool .

Manual Operation (Bypassing the Program)

Programmable Mode

Manual operation will bypass the program and allow you to 
adjust the temperature as you desire . The temperature you 
set in 

Hold

 will be maintained indefinitely . Press 

 or 

 to 

adjust the temperature . The HOLD key will appear . Press the 
HOLD key . "

Hold At"

 will appear next to the setpoint tem-

perature and the thermostat will maintain the new setpoint 
temperature until 

Run Schedule

 is pressed to resume pro-

gram operation .

PROGRAMMING

Set Current Time and Day

1 .  Press Menu key to enter installer menu . Then press
 

Set Time once to indicate hour & AM or PM designation  
in clock display .

2 .  Press and hold either the   or   touch key until you 

reach the correct hour and AM or PM designation .

3 .  Press Set Time again to display minutes only in clock 

display .

4 .  Press and hold either the   or   touch keys until you  

reach the correct minutes .

5 .  Press Set Time once again to display year .
6 .  Press either the   or   touch key until you reach the 

correct year .

7 .  Press Set Time once again to display month .
8 .  Press either the   or   touch key until you reach the 

correct month .

9 .  Press Set Time once again to display date of the month 

along with day of the week at top row (which is automatic) .

10 . Press and hold either the   or   touch key until you 

reach the correct day of the month and day of the week 
displayed at the top row .

11 . Press Run Schedule once or twice to remove the key . 

Now the display will show the correct time and room tem-
perature .

Automatic Daylight Saving Calculation

The Real Time Clock will adjust automatically for daylight sav-
ings time, in the following manner:
Increment one hour at 2 AM on the second Sunday of March 
and decrement one hour at 2 AM on the first Sunday of No-
vember . (New DST effective 2007) .

The daylight saving feature can be enabled or disabled in 
installer configuration menu . Default is 

DS ON

 (enabled) .

After entering installer configuration mode, momentarily
press touch key until the display indicates dS (in actual tem-
perature digits) and on (default – in clock digits) .   and   
keys will toggle display and operation from on to OFF .

Programming Tip: Copy Program

When programming your thermostat, you may copy the pro-
gram from one day to another day or group of days using the 

Copy

 key . In 7 day programming mode, a day can be copied 

to another day or all six other days . In 5/1/1 day programming 
mode the weekday (Mon – Fri) program can be copied into 
Sat and Sun or either Sat or Sun .
To copy a program from one day to another:
1 .  In Set Schedule mode, enter the program for the day or 

select the day you wish to copy by pressing 

Advance Day

 .

2 . Press 

Copy

 . The display will show

 “Copy”

 next to the 

SYSTEM

 key and the day of the week that will be copied .

3 . Press 

Advance Day

 . The day being copied will be indi-

cated and the other days will be flashing . 

4 .  If you wish to copy to all days skip to next step or press 

Advance Day

 until the day you wish to copy to is flashing .

5 . Press 

Copy

 .

 “Copy”

 will disappear, the day you copied 

from will disappear and the day(s) you copied to will be on .

6 .  If you wish to copy this same program into other days, 

press 

Copy

 and repeat steps 3, 4 and 5 .

7 . Press 

Run Schedule

 to return to normal operation .

Fill in the blank schedule on the next page then:

10

Содержание 1F95-1280

Страница 1: ... Thermostat Configuration Options Thermostat Applications Maximum Stages Heat Cool W Economizer Max Stage Heat Cool Single Stage 1 No Heat Pump SS1 Gas Oil Electric Heat Only Cool Only or Heat Cool Systems 2 or 3 wire Hydronic Zone Hot Water or Steam Systems 24 Volt or Millivolt 1 1 1 2 Multi Stage 2 No Heat Pump MS2 2 2 2 3 Heat Pump 1 Single Stage Compressor Heat Pump HP1 Single Stage Compressor...

Страница 2: ...he Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch options WARNING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code INSTALLATION Figure 1 Thermostat Base Multi Stage 1F95 1280 2 AA Batteries Power Stealing Switche...

Страница 3: ...gured for Electric Heat Installer Configuration Menu selects O or B for changeover function Set to O terminal energized in Cool mode Set to B terminal energized in Heat emergency mode Power closed connection for SPDT 3 wire zone valve Fault or system malfunction indicator for Heat Pumps with L terminal connection COOLING CLASS II TRANSFORMER HOT 24VAC NEUTRAL 120VAC HEATING 120VAC Dual fuel option...

Страница 4: ...2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 19 2 1 11 10 15 16 9 8 17 13 12 4 18 14 A steady Cool Savings display indicates the feature is enabled in the installer menu A flashing Cool Savings display indicates the feature is active 15 Remote indicates that the indoor remote temperature sensor is being accessed Outdoor Remote indi cates the outdoor remote temperat...

Страница 5: ...s Continuous Display backlight 12 LO dL HI Selects Backlight Intensity 13 0 Temperature 5 LO to 5 HI Selects Adjustable Ambient Temperature Display range 5 LO to 5 HI 14 F C Selects F C Display temperature units in Fahrenheit or Celsius 15 On b OFF Selects audible Beeper On Off 16 On dS OFF Selects Daylight Saving Time calculation 17 On Heat AS OFF Selects Automatic Schedule for comfort temperatur...

Страница 6: ...ctory default setting is fast cycle FA Cr in all modes Heat Cool Emer To change to slow cycling SL Cr press touch keys or toggle between FA SL The cycle rates are below Mode Fast rate Slow rate Heat SS1 MS2 0 6 F 1 5 F Cool SS1 MS2 1 2 F 1 7 F Heat Pump HP1 HP2 1 2 F 1 7 F Emer Heat HP1 HP2 0 6 F 1 7 F 10 Select Compressor Lockout CL Selecting CL On will cause the thermostat to wait 5 minutes betw...

Страница 7: ...tting between 62 F and 98 F Temperature Limit icon will be displayed to the left of your setpoint temperature when using this feature Temperature Limit icon will flash if an attempt is made to adjust the temperature beyond the range selected 23 Cool Temperature Limit Range This feature adjusts the lowest setpoint temperature for cool The default setting is 45 F It can be changed to a setting betwe...

Страница 8: ...eat will not turn on The default setting is 60 but can be set in the range of 5 to 79 INSTALLER CONFIGURATION MENU If indoor temperature drops below 45 because of a pos sible heat pump malfunction the thermostat will turn off the pump and switch to Auxiliary heat Call for Service will display on screen There are two ways the thermostat will return to normal heat pump operation Press any key to ret...

Страница 9: ...below room tempera ture The heating system should stop operating Cooling 1 Press SYSTEM to select COOL 2 Press to adjust the thermostat setting below room tem perature The blower should come on immediately on high speed followed by cold air circulation The display should show System On If the setpoint temperature display is flashing the compressor lockout feature is operating see Configuration men...

Страница 10: ...inutes only in clock display 4 Press and hold either the or touch keys until you reach the correct minutes 5 Press Set Time once again to display year 6 Press either the or touch key until you reach the correct year 7 Press Set Time once again to display month 8 Press either the or touch key until you reach the correct month 9 Press Set Time once again to display date of the month along with day o...

Страница 11: ...gram all the heating temperatures during the day to a comfortable temperature and then lower the temperature 6 at night Auto Schedule Cool will program all of the cooling time periods to the same temperature Note Auto Schedule is available only when the thermostat is first powered on after the thermostat has been reset or anytime you turn AS on in the Configuration Menu item 18 AS Heat or 19 AS Co...

Страница 12: ...cil in your own program times and temperatures The 1F95 1280 comes configured for 7 day programming and can also be configured for 5 1 1 programming see configura tion section Factory settings are listed on Monday Saturday and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a...

Страница 13: ...ration of the thermostat the current tempera ture displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight x local sensor temperature remote sensor weight x remote sensor temperature local sensor weight remote sensor weight Example Local sensor temperature is 80 and the remote sensor is 70 If weight is selected H4 the averaged temperatu...

Страница 14: ...stem operates correctly replace the thermostat Thermostat Setting Thermostat Thermometer Disagree 1 Thermostat thermometer setting requires adjustment The thermometer can be adjusted 4 degrees See Temperature Display Adjustment in the Configuration Menu section Furnace Air Conditioner Cycles Too Fast or Too Slow narrow or wide temperature swing 1 The location of the thermostat and or the size of t...

Страница 15: ...15 NOTES ...

Страница 16: ...White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 www white rodgers com www emersonclimate com ...

Отзывы: