Installation Manual

  

                                                                                                                                HVAC CONTROLS PRODUCTS

 

Touch Screen Weekly Programmable Underfloor Heating Thermostat 
Model No - E91.716 

 

This thermostat is designed for the control of electric underfloor heating systems. The weekly programming function allows 6 
time periods to be set per day, each at a specific temperature. Alternatively this model can be operated in manual mode. 

Temperature Sensors 

 
Sensor Selection 

To alter the sensor selection from the factory preset setting refer to the advanced settings section. 
Sensor Display 

 

 

IN 

Internal Air Sensor ONLY 

Heating will be switched on by the thermostat when the room temperature falls below the 
programmed temperature. There is 

NO LIMIT

 on the temperature the floor can reach.

 

OUT 

Floor Sensor 

Heating will be switched on by the thermostat when the floor temperature falls below the 
programmed temperature.

 

ALL 
 (Factory Preset) 

Air and Floor Sensor 

Heating will be switched on by the thermostat when the room air temperature falls below the 
programmed temperature. The thermostat will cut the power to the heating if the floor 
temperature rises above the temperature limit set. The value of this limit can be set within the 
advanced settings (factory set at 35ºC)   

 

If this thermostat is to be used with any under floor heating system designed for floor coverings other than ceramic, porcelain or stone 
floor tiles, ensure the limitation temperature value is set in accordance with the value recommended by your floor covering supplier.  

 
Sensor Error Indicator 

Please select the correct mode of internal, external sensor. The display will show Er0 or Er1 if the wrong mode is selected or there is sensor 
failure. Er0 means there is no internal sensor or there is internal sensor failure. Er1 means there is no external sensor or external sensor 
failure. The thermostat must not be used until the error has been resolved.  

 

Operating Instructions

 

 
                                                                                                                                            Technical Data 

Power Supply 

AC230V  

Max Load 

16A 

Power Consumption 

2W 

Setting Range 

5 - 90ºC 

Limitation Range 

5 - 60 ºC (Factory set @ 35ºC) 

Switching Differential 

0.5 - 10ºC (Factory set @ 1.0ºC) 

Ambient Temperature 

-5 - 50ºC 

Protective Housing 

IP20 

Housing Material 

ABS & PC Fire-resistant 

Certification 

CE & ROHS 

Floor Sensor 

Rubber-thermoplastic NTC 10K 

Internal Air Sensor 

NTC 10K 

 

User’s Daily Operation 

1.

 

To switch on or off press 

 

2.

 

To temporarily change the operating temperature when in program controlled mode, press 

 or 

 The 

temperature will revert back to pre programmed value at the next change of event. 

3.

 

To adjust the current time, hold 

for 5 seconds. Press 

again to select the required object. Press the 

or 

keys 

to adjust time & day, then switch off thermostat for confirmation. 

4.

 

To change between manual mode & program controlled mode, press

 

5.

 

To lock and unlock hold both the 

and 

keys together for 5 seconds. The 

symbol will appear when locked. 

6.

 

The large central temperature displayed is the measured temperature. The smaller value underneath which alternates 
with the time, is the target set temperature. 

7.

 

To enter advanced settings turn the thermostat off, then hold the 

key down and press 

simultaneously. 

 
HVAC CONTROLS PRODUCTS                                                                                                                                          DS/MRD-06-100114E

 