CH193

WEEKLY PROGRAMMABLE THERMOSTAT WITH 

TOUCHSCREEN

Summary of Contents for CH193

Page 1: ...CH193 WEEKLY PROGRAMMABLE THERMOSTAT WITH TOUCHSCREEN...

Page 2: ...MAINTENANCE QUICK GUIDE FOR PROGRAMMING description of keys display setting time and date operating programs settable temperatures setting operating programs FUNCTIONS IN DETAIL available programs se...

Page 3: ...Act on the master switch on the electric panel to cut power to the electrical system Connect the two wires of the boiler to terminals 1 2 of chronothermostat Connect the two power cables L N Screw th...

Page 4: ...ored thanks to an internal battery ATTENTION installation must be carried out by qualified personnel 230V 50Hz CH193 Sonda AUX attivatore telefonico CT3M MA caldaia 2 L N 1 3 4 2 1 N B When CH193 is d...

Page 5: ...EL DISP JOLLY OFF COPY F QUICK GUIDE FOR PROGRAMMING 5 DESCRIPTION OF KEYS DISPLAY The chronothermostat is equipped with 6 keys the function of which varies depending on the situation It is described...

Page 6: ...half hour but the identical sequence will be repeated every day SEL TEMP PROG DISP JOLLY OFF HOLIDAY SETTING TIME AND DATE After the device switches on press the key PROG briefly the text Setup is di...

Page 7: ...e heating system from freezing MAN JOLLY SETTABLE TEMPERATURES Four different temperatures can be set and one can be selected for each half hour of the day in the AUTO and HOLIDAY programs Three of th...

Page 8: ...op at the T you want to change and use the arrow keys and to increase or decrease the temperature by a tenth of degree at a time Press to go back to the initial status Remember that T1 will always be...

Page 9: ...o choose the desired temperature T1 T2 T3 Ta for each half hour of the indicated day from 1 to 7 indicating the days from Monday to Sunday PLEASE NOTE T1 T2 T3 Ta are displayed on the right of the scr...

Page 10: ...n this time elapses you go back to the initial program OFF ANTIFREEZE PROGRAM SETTING Pressing OFF from any program switches the chronothermostat to the off antifreeze status The antifreeze temperatur...

Page 11: ...d from 1 to 7 and correspond to the seven days of the week starting from Monday To simplify programming you may set the first day and copy it on the following days The default for days 1 5 Monday to F...

Page 12: ...0 11 30 T2 11 30 23 00 T3 23 00 24 00 T1 The value of the temperatures can be programmed using the TEMP function The temperature profile hourly variation can be programmed using the PROG function 8 11...

Page 13: ...to switch the boiler completely off Weekly or daily programs remain unchanged settable TEMPERATURES The system can use 4 different temperature levels three for normal use and one called antifreeze to...

Page 14: ...OFF Pressing TEMP allows you to enter programming of the 4 temperatures used in these statuses Change the temperatures using the arrow keys and as long as T1 is no higher than T2 T2 is not lower than...

Page 15: ...t pressing cyclically increases the days while decreases them press to change page and press ENTER to exit PROG PLEASE NOTE when the date is set the chronothermostat automatically determines the day o...

Page 16: ...placed at the desired height area Use and to modify the temperature value on the display Press to go to page 2 and ENTER to exit Celsius PG02 XX X This allows you to choose the temperature display sca...

Page 17: ...displayed restores all the parameters except date and time to the default values Press to go to page 8 and ENTER to exit CH193 vX Y PG08 Displays the software version of the CH193 chronothermostat Pr...

Page 18: ...ress to go to the next page and ENTER to exit BEEP ON OFF PG14 enables or disables the beep upon pressing a key The selection is made by pressing and Press to go to the next page and ENTER to exit LED...

Page 19: ...HH h MM m hour min Tamb Using the arrow keys and allows you to change the duration of the JOLLY status with hourly steps The Jolly temperature is set by pressing the key TEMP which displays a window...

Page 20: ...ing facilities A black bar indicates that the product was placed on the market after August 13th 2005 Participating in the separate collection of products and batteries contributes to the correct disp...

Page 21: ...sconnection Software class A Minimum adjustment differential 0 1 C Thermal gradient of reference 4K h Maximum room temperature T45 Electric insulation double insulation Degree of protection IP20 Pollu...

Page 22: ...f to an interval between 2 0 and 7 0 C using the arrow keys and The following window is displayed Ta x x hour min Tamb To go back to the OFF window press the arrow key Pressing OFF again sends you bac...

Page 23: ...Intellicomfort CH193 23...

Page 24: ...ANTINI COSMI S p A Via dell Osio 6 20090 Caleppio di Settala Milano ITALY Tel 39 02 956821 Fax 39 02 95307006 info fantinicosmi it EXPORT DEPARTMENT Ph 39 02 95682229 export fantinicosmi it www fantin...