Summary of Contents for DT-W

Page 1: ...Model DT W REF DT W Revision 1 1 12 11 ...

Page 2: ......

Page 3: ...rocedure 2 3 Pairing the Thermostat 4 7 Icons Explained 8 Temperature Display 8 Setting the Temperature 9 Locking the Thermostat 9 Turning the Heating On Off 9 Factory Reset 10 Optional Feature Setup 11 16 Wiring Diagram 17 1 ...

Page 4: ...2 4 4 4 4 ...

Page 5: ...3 4 1 9 1 4 4 4 1 4 A ...

Page 6: ... corner of the LCD is the feature number Press Clock repeatedly until you see feature 06 Receiver Type The options within feature 06 are 00 UH1 W or 01 RC1 W receiver Use the Up Down keys to set feature 06 to 01 RC1 W Press Clock again until you see feature 07 Receiver Address You can now select a Receiver Address from 01 32 Use the Up Down keys to set feature 07 to 01 You should set a unique rece...

Page 7: ...nk Pairing the thermostat Comms LED comes on 5 seconds The thermostat will send a signal for 1 minute and will flash the RF signal icon If successful the Comms LED on the receiver will flash pairing If the pairing is unsuccessful check features 06 to 08 have been configured correctly to eliminate a possible signal issue repeat the pairing process again ...

Page 8: ...t on the rotary switch Board ID number 1 9 Each UH1 W on the system will need a different ID number With the thermostat turned off numbers appear The small number 01 in the top right corner of the LCD is the feature number RC1 W receiver Use the Up Down keys to set feature 06 to 00 UH1 W Address ...

Page 9: ... should be linked to Press Clock again until you see feature 09 00 Under floor heating 01 Radiators Use the up down buttons to select if the thermostat is controlling Under Floor heating or radiators Press A to accept the display will now go blank Press the power button once to turn the thermostat back on press the up button set the target temperature above the room temperature the flame symbol shou...

Page 10: ...8 He ng On He ng Off Frost Mode Key Lock RF Signal Ac ve Ba ery ...

Page 11: ...9 ...

Page 12: ... 10 ...

Page 13: ...11 ...

Page 14: ... Delay To prevent rapid switching and output delay can be entered This can be set from 00 15 minutes The default is 00 which means there is no delay Feature 06 UH1 W or RC1 W receiver The thermostat can work with our UH1 W 8 zone wiring centre or RC1 W Feature 07 Receiver Address Within one building up to 9 UH1 W s or 32 RC1 W s can be used Each receiver must have a unique receiver address ...

Page 15: ...1 W receiver 01 08 UH1 W 01 02 RC1 W pump boiler output on the UH1 W If set to 00 the outputs will Feature 10 Fail Safe If enabled the thermostat will send a signal to the receiver every 20 minutes Should the receiver fail to receive two signals the protect the system against a loss of wireless signal or should the ...

Page 16: ...14 Feature 11 Up Down Temperature Limit temperature keys This limit is also applicable when the thermostat is locked and so allows you to give others limited ...

Page 17: ...15 01 03C 01C Default 04 Frost Temperature 07 17C 12C Deafult 05 Output Delay 00 15 Minutes 00 Default 06 UH1 W or RC1 W 00 UH1 W Receiver 01 RC1 W 00 Default ...

Page 18: ...ddress RC1 W 01 32 00 Default 08 Zone Number UH1 W 01 08 RC1 W 01 02 09 Underfloor Heating or Underfloor Heating Radiator 00 UH1 W Only Radiator Zone 01 10 Fail Safe 00 Disabled 01 Enabled 00 Default 11 Up Down Limit 00 10C 00C Default ...

Page 19: ...17 REMOTE AIR PROBE RED WIRE Set feature 12 to 01 to enable the remote air probe WHITE WIRE ...

Page 20: ......