background image

1

GB

 Digital In-Out Thermometer

  with RF Clock & Photo Frame

MODEL: RMR232PHN/RMR232PHU (UK Version)

USER'S MANUAL

INTRODUCTION

Congratulations on your purchase of the RMR232PHN/
RMR232PHU, an In-Out Thermometer with Radio-Controlled Clock
and a Photo Frame attached.

The basic package comes with the following:

--

Main unit (RMR232PHN/RMR232PHU).

--

Remote thermo sensor unit

--

Blue and metallic grey exchangeable front key panels.

The main unit shows the indoor temperature, calendar clock and
temperatures collected and transmitted by the remote unit.

The main unit is also capable of keeping track of the maximum and
minimum temperature measured. No wire installation is required
and the RMR232PHN/RMR232PHU operates at 433MHz.

As for the calendar clock, it is radio-controlled. It automatically
synchronizes its current time and date when it is brought within an
approximate 1500km radius of the radio signal generated from
Frankfurt, Germany (DCF77). (MSF 60 for UK Version)

You can also set the calendar clock manually when it is off range.
Other features include five-language display and two-minute
crescendo daily alarm.

MAIN FEATURES: MAIN UNIT

K

A

B

C
D

E

F

H

I

P

J

N LM

O

O

G

Summary of Contents for RMR232PHN

Page 1: ...mperatures collected and transmitted by the remote unit The main unit is also capable of keeping track of the maximum and minimum temperature measured No wire installation is required and the RMR232PHN RMR232PHU operates at 433MHz As for the calendar clock it is radio controlled It automatically synchronizes its current time and date when it is brought within an approximate 1500km radius of the ra...

Page 2: ...ting G ALARM BUTTON Displays the alarm time or sets the alarm status H FRONT PANEL Exchangeable front panel with clip on design I UNLOCK BUTTON Unlock the photo frame drawer J PHOTO FRAME DRAWER Holds photo in position K PHOTO FRAME COVER Protects photo from finger prints and other damages L RESET BUTTON Returns all settings to default values M C F BUTTON Selects between degree Centigrade C and Fa...

Page 3: ...eption of signals 3 Position the remote unit and main unit within effective transmission range which in usual circumstances is 20 to 30 meters Note that the effective range is vastly affected by the building materials and where the main and remote units are positioned Try various set ups for best result Though the remote units are weather proof they should be placed away from direct sunlight rain ...

Page 4: ... batteries MU 3 or AA size 1 5 V strictly according to the polarities shown 3 Replace the battery compartment door and secure its screws LOW BATTERY WARNING When it is time to replace batteries the respective low battery indicator will show up on the indoor or outdoor temperature display HOW TO INSERT A PHOTO 1 Push the UNLOCK button to unlock and take out the photo frame drawer ...

Page 5: ...he photo frame 8 x12 cm 3 15 x 4 72 9 x13 cm 3 54 x 5 12 10 x15 cm 3 94 x 5 9 HOW TO USE THE TABLE STAND OR WALL MOUNTING The main unit has a table stand which can support the unit on a flat surface Or you can mount the unit on a wall using the recessed screw hole As for the remote unit you can place it on a flat surface or mount the unit on a wall using the recessed screw hole Main unit Wall moun...

Page 6: ...wave display shows the signal receiving status of the main unit There are three possible forms THE RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button All settings will return to their default values GETTING STARTED Once batteries are in place for the remote unit they will start transmitting temperature...

Page 7: ... is still in place 2 The batteries of both the remote unit and main unit Replace as necessary Note When the temperature falls below freezing point the batteries of outdoor units will freeze lowering their voltage supply and the effective range 3 The transmission is within range and path is clear of obstacles and interference Shorten the distance when necessary TRANSMISSION COLLISION Signals from o...

Page 8: ...activated When the unit is receiving radio signal the radio reception signal will start to blink A complete reception generally takes about 2 to 10 minutes depending on the strength of the radio signal When the reception is complete the radio reception signal will stop blinking The strength of the reception for the last full hour will be indicated For better reception place the clock away from met...

Page 9: ...e unit to stop the alarm sound HOW TO SET THE CALENDAR CLOCK MANUALLY To set the clock manually hold MODE SET for two seconds in clock display mode The 12 hr or 24 hr display will blink Use or to select 12 hour or 24 hour format Press MODE SET to confirm Repeat the same procedure to set the hour minutes year month day and display language During the setting press and hold or will increase or decre...

Page 10: ...batteries as the old ones may leak 6 Always read the user s manual thoroughly before operating the unit 7 Note No rechargeable batteries should be used in this product Only use the type of battery as specified SPECIFICATIONS Temperature Measurement Main unit Indoor Temperature measurement Proposed operating range 5 0 C to 50 0 C 23 0 F to 122 0 F Temperature resolution 0 1 C 0 2 F Remote unit Prop...

Page 11: ... of the R TTE Directive applied standard s ETS 300 683 1997 Safety of information technology equipment Article 3 1 a of the R TTE directive applied standard s EN 60950 1997 Additional information The product is therefore conform with the Low Voltage Directive 73 23 EC the EMC Directive 89 336 EC and R TTE Directive 1999 5 EC appendix II and carries the respective CE marking VS Villingen Germany Au...

Reviews: