background image

 
 

User’s Manual- Installation and Operation

 

Important Safety Information 

 

Always turn off the main power when the plastic cover of the thermometer is removed. 

 

Read carefully the information included in this manual before install for operation the thermometer. 

 

The used power is the main power of 230Volts AC/50Hz and the installation should be done by authorized person. 

 

Avoid places of high humidity for the installation. 

 

Do not try to use the thermostat for other applications except those that is made to be used i.e. double or triple heating source 

boilers. 

 

This thermometer is not an instrument. It must not be used in life critical applications. 

 

Features 

 

Senses and displays the temperature from -5°C to +90°C. 

 

Adjustable from -5°C to +90°C. 

 

Adjustable high and low temperature limits. 

 

Displays “Lo” and “Hi” indication when temperature reaches the lower or the upper limit. 

 

Displays “Err” indication and deactivates the relay in case of remote sensor disconnect. 

 

Temperature can be adjusted in steps of 0.1°C. 

 

The accuracy is within ±2°C. 

 

Memory is available in case power failure. 

 

Contains light indicators for “SET”, “ON/OFF”, and “ORDER” conditions. 

 

It is internally protected against lightings. 

 

It is galvanically isolated. 

 

 Incorporates variable differential and sensed temperature trimming function (for installers only). 

 

Installation 

Install the thermometer always in an inside wall in a height of 1.2m to 1.5m from the floor in order to be easy readable. 

1.

 

Turn OFF the power of the installation. 

2.

 

Remove the plastic cover of the thermometer simply by pressing the two anchors in both lateral sides. 

3.

 

Place thermometer against the wall at desired location. Make sure the wires will feed through opening on its base. 

4.

 

Mark the position of mounting holes and drill them. 

5.

 

Secure and align the thermometer in the wall by fixing the two screws. Do not over tighten the screws. 

6.

 

Install the remote sensor in contact to the boiler that has to be sensed. For better result place the sensor between the metal container 
and the isolation coating. It is allowed to extend the remote sensor cable by using a double wire, multi strand cable with cross 
section at least 1mm

2

 . Do not extend the sensor more than 25m. The remote sensor is not water resistant. Do not immerse the 

sensor into the water or other liquids. 

7.

 

Connect the appropriate wires to cable terminal strip as shown in the wiring diagram. 

8.

 

Replace the plastic cover. Switch ON the power of the installation.

 

 

Operation 

When the installation is accomplished the device operates as a digital thermometer. Press the “ON/OFF” button. A green indicator  lights 
on. Repressing the same as above “ON/OFF” button the thermostat goes OFF. Adjustment of  the desired temperature when thermostat is 
ON is made by pressing either the button signed with 

 or 

 symbols. A yellow colored indicator lights on and the display shows the 

desired temperature. Once the desired temperature is set up correctly the thermostat affects system in order to maintain the boiler 
temperature as close as possible into the setting. When the temperature is lower than the desired the red indicator lights on and the electrical 
contact is closed. When the temperature exceeds the desired point the red indicator is switched off and the electrical contact opens.  
The thermostat has a factory preprogrammed differential of -3°C which is well suited for domestic water heating applications. The 
temperature differential can be adjusted from –0.1°C to –10.0°C. Differential adjustments must be done exclusively from authorized 
personnel. Incorrect adjustment has serious danger and may affect the correct operation as well as the stability of the system. For the same 
reason take care when performing trimming to improve sensed temperature accuracy. This adjustment is also allowed to experienced 
installers only. Refer to Charmeg for detailed trimming procedures.   
     
This product has been manufactured from materials which can be recycled and reused according  to the European Directive 
2002/96/EC. 
Please be informed regarding the local collection system for electrical and electronic equipment and do not dispose the old 
products with your normal household waste. 
The correct disposal of the products will help to prevent the negative consequences of the environment and human health.

 

 

Technical Characteristics

 

Physical dimensions 

110x62x31mm approx. 

Mains power 

~230V AC/50Hz ±10% 

Electrical contact rating  

5A/250VAC  5A/30VDC 

Adjust limits 

-5 °C to +90 °C 

Differential 

-3°C(-0.1°C to -10.0°C for authorized personnel) 

Sensed temp. trimming 

-3.0°C to +3.0°C (for authorized personnel) 

Operating temperature 

-10°C to +50°C 

 

 

Temperature

Decrease button

ON/OFF button

ORDER

indicator

ON indicator

Temperature

Increase button

SET mode

 indicator

Display

L

at

er

al

 A

nc

ho

r

L

ate

ra

l A

nc

ho

r

Outside front view

MP-T

 

Wire Pass Through Opening

Wire Terminal Strip

Mounting Hole

Mounting Hole

L

ate

ra

l A

nc

ho

r

L

at

er

al

 A

nc

ho

r

Remote Sensor Connector

 

 

Re mote 

Sensor

A

B

230V AC

Electrical Contact

Wiring diagram

4 3 2 1

L   N

Example for 230V burners

4 3 2 1

To burner

Short circuit

230V AC

L   N

230 V AC

L   N

 

 

 

MP-T

  

 

Digital Thermostat and Boiler Thermometer

 

 

27 Kotronos str. Aegaleo-Athens- Greece 

 

Tel. +030 210 5693111, Fax.+030 210 5693093, 

www.charmeg.gr

               

Doc

: MP T Users manual 7.docx

 

Reviews: