Summary of Contents for Halo Combi RF

Page 1: ...w w w i d e a l b o i l e rs com Halo Combi RF I n s t a l l a t i o n G u i d e...

Page 2: ......

Page 3: ...h the Halo Smart Interface installed in the boiler The Halo Smart Interface plugs into the front aperture on the boiler and communicates to the boiler via OpenTherm The Halo unit is powered by 4 AA ba...

Page 4: ...nsation controller as indicated This product is compatible with the boiler and provides compensation control that has been permanently enabled The boiler has been commissioned in accordance with the m...

Page 5: ...rames or solid concrete walls If the distance between the Halo and Smart Interface is above 30 metres or the install location is challenging consider using the Ideal Zigbee Booster Product Code 221132...

Page 6: ...sing and clip into place 2 If no trim plate is required use the rear housing of the Halo to position the unit on the wall alternatively secure rear housing to trim plate Take care not to overtighten t...

Page 7: ...d rear housing and desk stand 2 Insert the 4 AA batteries provided into the front housing of the Halo Pay close attention that the orientation of the batteries is as indicated in the housing 3 Clip th...

Page 8: ...m connection see diagram On brand new boilers the link should already be in place 2 Locate the wiring terminals 230V connections are on the left and low voltage on the right 3 If existing 230V device...

Page 9: ...the aperture 8 Push fit the Halo Smart Interface into the boiler aperture 5 Locate the blanking plate on the front of the boiler and remove carefully with a small flat bladed screwdriver 6 Remove lin...

Page 10: ...ch off the boiler the Override LED should now go out 11 Press and hold the Pair button on the Smart Interface until the Zigbee LED starts flashing red to begin the pairing process with the Halo 9 Swit...

Page 11: ...Complete when the Halo has successfully connected to the Smart Interface 5 The device will automatically prompt set up of the time and date 6 There is the opportunity to add an installer contact phon...

Page 12: ...he device setup should be set by a competent person Landlord settings Specific settings for landlords SMART INTERFACE LED KEY LED Status Power Green Power ON No illumination No Power Boiler Green Dema...

Page 13: ...erature at the time specified OFF Delayed start If the room temperature is close to target temperature the heating start time is delayed to save energy OFF Display tolerance Select the display toleran...

Page 14: ...RT access via the menu Target RSSI between 0 and 65 and text green On the Halo set the mode to AUTO then increase the temperature to 30 C Flame ON Boiler ON Boiler LED on Smart Interface ON Green On t...

Page 15: ...rface or are not replacing an existing Halo then press accept In the support page the Zigbee RSSI is lower than 65 and text red Consider moving the Halo closer to the Smart Interface If the situation...

Page 16: ...compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address www idealboilers com UIN 223827 A02 Ideal Boilers Ltd National Av...