![EMC Connectrix ED-64M Скачать руководство пользователя страница 311](http://html1.mh-extra.com/html/emc/connectrix-ed-64m/connectrix-ed-64m_user-manual_2399809311.webp)
A
Connectrix Private Enterprise MIB (fceos.mib)
A-95
Using SNMP to Manage the Switch
fcEosPortTxC2Words64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of class 2 4-byte words that
the port has transmitted. (Primitive signals and primitive
sequence are not included.)
fcEosPortRxC2Words64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of class 2 4-byte words that
the port has received. (Primitive signals and primitive
sequence are not included.)
fcEosPortTxC2Frames64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of Class 2 frames that the
port has transmitted.
fcEosPortRxC2Frames64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of Class 2 frames that the
port has received.
fcEosPortTxC2Octets64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of Class 2 Octets that the
port has transmitted.
fcEosPortRxC2Octets64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of Class 2 Octets that the
port has received.
fcEosPortTxC3Words64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of class 3 4-byte words that
the port has transmitted. (Primitive signals and primitive
sequence are not included.)
fcEosPortRxC3Words64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of class 3 4-byte words that
the port has received. (Primitive signals and primitive
sequence are not included.)
fcEosPortTxC3Frames64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of Class 3 frames that the
port has transmitted.
fcEosPortRxC3Frames64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of Class 3 frames that the
port has received.
fcEosPortTxC3Octets64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of Class 3 Octets that the
port has transmitted.
fcEosPortRxC3Octets64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of Class 3 Octets that the
port has received.
fcEosPortC3Discards64
OCTET STRING
(SIZE (8))
PSCC
R
A 64 bit counter for the number of Class 3 frames that the
port has discarded
fcEosPortTxFlows
Counter
PSCC
R
A 32 bit counter for the number of flows rerouted from this
port.
fcEosPortRxFlows
Counter
PSCC
R
A 32 bit counter for the number of flows rerouted to this port.
Table A-44
Port Table (continued)
FCEOS MIB Object
Name
Type
Provid
ed By
Access Description
Содержание Connectrix ED-64M
Страница 4: ...Connectrix ED 64M User Guide iv...
Страница 18: ...xviii Connectrix ED 64M User Guide Figures...
Страница 26: ...xxvi Connectrix ED 64M User Guide Preface...
Страница 30: ...xxx Connectrix ED 64M User Guide Warnings and Cautions...
Страница 60: ...2 2 10 Connectrix ED 64M User Guide Operating the Director...
Страница 86: ...3 3 26 Connectrix ED 64M User Guide Product Manager Overview...
Страница 326: ...B B 8 Connectrix ED 64M User Guide Configuring Network Addresses...
Страница 334: ...D D 6 Connectrix ED 64M User Guide Configuring Embedded Web Server Passwords...
Страница 442: ...F F 4 Connectrix ED 64M User Guide Specifications...
Страница 450: ...G G 8 Connectrix ED 64M User Guide Customer Support...
Страница 476: ...Connectrix ED 64M User Guide i 8 Index...