Fibre Alliance MIB (fcmgmt.mib)
A-75
Using SNMP to Manage the Switch
FcConnUnitPortStatCountTxElements
Counter64
R
stTxOctets (64 bit counter)
The number of octets or bytes that have been transmitted by this port. One
second periodic polling of the port. This value is saved and compared with
the next polled value to compute net throughput. Note, for Fibre Channel,
ordered sets are not included in the count.
FcConnUnitPortStatCountRxElements
Counter64
R
stRxOctets (64 bit counter)
The number of octets or bytes that have been received by this port. One
second periodic polling of the port. This value is saved and compared with
the next polled value to compute net throughput. Note, for Fibre Channel,
ordered sets are not included in the count.
FcConnUnitPortStatCountBBCreditZero
Counter64
R
Not supported
Count of transitions in/out of Bbcredit zero state. The other side is not
providing any credit. Note, this is a Fibre Channel stat only.
FcConnUnitPortStatCountInputBuffersFull
Counter64
R
Not supported
Count of occurrences when all input buffers of a port were full and outbound
buffer-to-buffer credit transitioned to zero. There is no credit to provide to
other side. Note, this is a Fibre Channel stat only.
FcConnUnitPortStatCountFBSYFrames
Counter64
R
Not supported
Count of times that FBSY was returned to this port as a result of a frame that
could not be delivered to the other end of the link. This occurs if either the
Fabric or the destination port is temporarily busy. Port can only occur on
SOFc1 frames (the frames that establish a connection). Note, this is a Fibre
Channel only stat. This is the sum of all classes. If you cannot keep the by
class counters, then keep the sum counters.
FcConnUnitPortStatCountPBSYFrames
Counter64
R
Not supported
Count of times that PBSY was returned to this port as a result of a frame that
could not be delivered to the other end of the link. This occurs if the
destination port is temporarily busy. PBSY can only occur on SOFc1 frames
(the frames that establish a connection). Note, this is a Fibre Channel only
stat. This is the sum of all classes. If you cannot keep the by class counters,
then keep the sum counters.
Table A-36
Port Statistics Table (continued)
FA MIB Object Name
Type
Access
Product Mapping
Description
Содержание Connectrix ED-64M
Страница 4: ...Connectrix ED 64M User Guide iv...
Страница 18: ...xviii Connectrix ED 64M User Guide Figures...
Страница 26: ...xxvi Connectrix ED 64M User Guide Preface...
Страница 30: ...xxx Connectrix ED 64M User Guide Warnings and Cautions...
Страница 60: ...2 2 10 Connectrix ED 64M User Guide Operating the Director...
Страница 86: ...3 3 26 Connectrix ED 64M User Guide Product Manager Overview...
Страница 326: ...B B 8 Connectrix ED 64M User Guide Configuring Network Addresses...
Страница 334: ...D D 6 Connectrix ED 64M User Guide Configuring Embedded Web Server Passwords...
Страница 442: ...F F 4 Connectrix ED 64M User Guide Specifications...
Страница 450: ...G G 8 Connectrix ED 64M User Guide Customer Support...
Страница 476: ...Connectrix ED 64M User Guide i 8 Index...