background image

1

Overview

Some functions described in this document may not be supported by all revisions of the 
software or hardware currently in use. For the most up-to-date information on product 
features, refer to your product release notes.

A basic CLARiiON® CX3-40c storage system contains the following:

A storage processor enclosure (SPE3) with two storage processors (SPs) and 
redundant power/cooling. Each SP includes both Internet SCSI (iSCSI) and Fibre 
Channel host data ports.

At least one disk-array enclosure (DAE3P) with a minimum of five Fibre Channel 
disk modules.

 Two standby power supplies (SPS).

This guide explains how to install and initialize a CX3-40c in a Windows 
environment. It describes the major steps involved in adding storage-system 
hardware (sometimes called an array) to an existing storage configuration, or 
creating a new environment of servers and storage. Those steps include:

Preparing your site, planning the network configuration, and verifying your 
environment to avoid pitfalls and address potential obstacles to a successful 
installation before you encounter them

Connecting to a management station and initializing the system using a utility 
that assigns network and security characteristics to each SP and IP addresses to 
iSCSI data ports 

Readying every server that will connect to the storage system, then establishing 
physical and virtual connections between the storage system and servers

Verifying the system and failover configurations

Once your system is up, initialized, and running, you should refer to other sources for 
information on planning or implementing data storage. The Documentation and Resources for 
CX3-Series Storage Systems 
CD that shipped with the storage system includes detailed 
documents related to the storage system. The most recent versions of relevant documents, 
including software release notes, are available in the Documentation/White Paper Library 
section of the Powerlink® site (

http://Powerlink.EMC.com

). 

Содержание CLARiiON CX3-40c

Страница 1: ...EMC CLARiiON CX3 40c Setup Guide P N 300 003 745 REV A02...

Страница 2: ...ION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR...

Страница 3: ...s include Preparing your site planning the network configuration and verifying your environment to avoid pitfalls and address potential obstacles to a successful installation before you encounter them...

Страница 4: ...ng the EMC Installation Roadmap for CX3 Series CX Series AX Series and FC Series Storage Systems The roadmap provides detailed checklists of installation procedures for supported storage system enviro...

Страница 5: ...this host To initialize the storage system To run the Navisphere Service Taskbar As a Navisphere management station The management station can be any Windows host with the required Java runtime envir...

Страница 6: ...figurations but recommends discrete networks that are dedicated to iSCSI data traffic Each storage processor has four iSCSI ports for connecting the storage system either directly or through a network...

Страница 7: ..._____ _____ _____ _____ SP B 0 iSCSI _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ SP B 1 iSCSI _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ SP B...

Страница 8: ...t the Wizards tab 4 Select the Storage Array Wizard from the drop down menu a For each step of the wizard provide the requested information based on what you intend to attach to your storage system Th...

Страница 9: ...talled on your CX3 40c shipped with the storage system You will install PowerPath or a PowerPath upgrade later as part of Install Step 7 in this guide If any other element of your projected storage sy...

Страница 10: ...RI ports on the first DAE3P in their respective loops The DAE3P expansion EXP ports connect to the next PRI ports in their loops Each bus includes up to 8 DAE3Ps 120 disks EXP PRI EXP PRI EXP PRI EXP...

Страница 11: ...binet Power cooling module A in the first DAE3P EA 0 bus 0 connects to SPS A power cooling module B in the first DAE3P connects to SPS B Subsequent DAE3Ps connect directly to the cabinet s PDUs Power...

Страница 12: ...EXP PRI A B EXP PRI EXP PRI EXP PRI EXP PRI A B EXP PRI EXP PRI EXP PRI EXP PRI A B EXP PRI EXP PRI EXP PRI EXP PRI A B EXP PRI EXP PRI EXP PRI EXP PRI A B EXP PRI EXP PRI EXP PRI EXP PRI A B EXP PRI...

Страница 13: ...g power on self test POST and then go off The front fault light and the SPS recharge lights commonly stay on for several minutes while the SPS units fully charge If any amber lights on the front or ba...

Страница 14: ...h you will manage the storage system the management station To initialize the storage system you will need a host connected to the same subnet as the storage system s SP This host can be the managemen...

Страница 15: ...o be a server and is often your management station The completed configuration planning worksheets from the planning section of this guide page 5 The CLARiiON Core Server Support CD that shipped with...

Страница 16: ...ts all uninitialized and initialized CLARiiON storage systems that it found Uninitialized systems are identified by hardware serial number On a CX3 40c storage system the hardware serial number TLA S...

Страница 17: ...ter your storage system with your provider now If you decide not to register your storage system at this time or you do not have Internet email you can still run the wizard to collect the data and sen...

Страница 18: ...Service Taskbar from the CLARiiON tools page on the Powerlink site Install it on a Windows host that is connected to the same network as the storage system management ports b Start the Navisphere Ser...

Страница 19: ...ments we strongly recommend that you set up the Fibre Channel or iSCSI installation and confirm its error free operation before you set up the second environment The first set of instructions beginnin...

Страница 20: ...snap and or admhost software on any hosts that will use SnapView or SAN Copy Install HBAs and drivers On each server install HBAs the appropriate drivers and any required driver updates such as servic...

Страница 21: ...w accepting all the defaults Install admsnap and or admhost software If you installed the SnapView and or SAN Copy enabler on the storage system then the servers that use SnapView require admsnap soft...

Страница 22: ...ase of Use zoning wizard to guide you through setting up the switch cabling and zoning the hosts to the storage system If you use the zoning wizard skip the next step Step 9 of this guide and continue...

Страница 23: ...ect configuration between a storage system and server connect the cables to Fibre Channel HBA ports as shown below For a switch configuration between a storage system and server connect the cables to...

Страница 24: ...tall Step 10 Fibre Channel Register the Fibre Channel HBAs On each server that uses a Fibre Channel host bus adapter run the server utility to register the HBAs with the storage system 1 Start the ser...

Страница 25: ...error free operation before you set up a second environment To do so skip steps 7 10 iSCSI now and continue with Step 11 Verify the storage system and high availability configuration on page 32 After...

Страница 26: ...torage system iSCSI ports Install network interface cards NICs and iSCSI host bus adapters HBAs and their drivers this page Install NIC or HBA initiator configuration software page 25 Assign IP addres...

Страница 27: ...h for iscsi initiator 4 Select and download the latest supported initiator software and related documentation On servers with iSCSI HBAs do not select or download the Software Initiator option For inf...

Страница 28: ...ent software If you have path management software other than PowerPath install it on each server as described in the software documentation Install PowerPath on each server as follows 1 Locate the Pow...

Страница 29: ...r configuration includes switches or routers install or upgrade any switch router software or patches for switches connected to the storage system and the servers See the installation manuals that shi...

Страница 30: ...on between the storage system and the server connect the Ethernet cables to the iSCSI initiator ports NICs or iSCSI HBAs as shown below For a network configuration between the storage system and the s...

Страница 31: ...e Server Utility 2 Select Configure iSCSI Connections on this server and click Next 3 Select Configure iSCSI Connections and click Next 4 In the iSCSI Targets and Connections window select one of the...

Страница 32: ...NIC that is in standby mode 8 If you selected Also login to peer iSCSI target for High Availability recommended in the previous step leave the Server Network Adapter IP set to Default This allows the...

Страница 33: ...in the QLogic documentation 2 Start the Navisphere Server Utility Start Programs EMC Navisphere Navisphere Server Utility 3 Select Register this server to all connected storage systems and click Next...

Страница 34: ...sts any problems try to resolve them For problem solving assistance see the troubleshooting flowcharts for the CX3 series storage systems on the Powerlink site Verify your high availability configurat...

Страница 35: ...station running CLARalert software You can upgrade the CLARalert software on the monitor station If you have an existing monitor station running Event Monitor You can install CLARalert software on the...

Страница 36: ...en Navisphere Manager right click the storage system and choose Properties On the Memory tab set the write cache to the maximum allowed and then allocate the remainder to read cache then click Apply O...

Страница 37: ...u need help To plan your entire installation generate a customized configuration guide from the Powerlink website or refer to the non customized version on the Documentation and Resources for CX3 Seri...

Отзывы: