Install - Step 9 continued (Fibre Channel)
Connect Fibre Channel data ports
Zone switches
If your configuration uses Fibre Channel switches without hard-wired zones, zone
them now. We recommend that you use single-initiator zoning, which limits a zone to
a single HBA port with one or more storage-system SP ports. Make sure that each
HBA is zoned to at least one port on each SP.
Install - Step 10 (Fibre Channel)
Register the Fibre Channel HBAs
On each server that uses a Fibre Channel host bus adapter, run the server utility to
register the HBAs with the storage system.
1. Start the server utility:
Start > Programs > EMC > Navisphere > Navisphere Server Utility
2. Select Register this server to all connected storage systems, and click Next.
3. Click Next to send the server information to the storage system.
4. Click Finish to exit the utility.
The utility sends the initiator records for the HBA initiators in the server to each
storage system that is connected to the server.